FRANKLIN PARK, IL —
OSHA Inspection: FERVALUE USA INC. DBA FERRERO U.S.A., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FERVALUE USA INC. DBA FERRERO U.S.A., INC. in 3401 MT. PROSPECT ROAD, FRANKLIN PARK, IL 60131 (NAICS 311340). OSHA activity number 345192926.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FERVALUE USA INC. DBA FERRERO U.S.A., INC.
- Site address
- 3401 MT. PROSPECT ROAD
- City
- FRANKLIN PARK
- State
- IL
- ZIP
- 60131
- Mailing
- 3401 MT. PROSPECT ROAD, FRANKLIN PARK, IL 60131
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311340
- Employees
- 700
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Aug 13, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $13,653 · Current $9,558 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a) Line 11 ? In or about March of 2021, the employer failed to provide an energy control procedure with clear and specific techniques to be utilized to isolate energy to the in-running nip point at the motor casing for the Line 11 Full Case Incline Conveyor during operations covered by this standard. b) On or about March 23, 2021, employees were exposed to machine hazards associated with moving parts and in running nip points from the Line 11 Full Case Incline Conveyor when tracking the belt. The employer failed to implement energy control application steps as the machines were not shut down or turned off to perform troubleshooting operations [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards. In accordance with 29 CFR 1910.147(c)(4)(ii)(B), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $9558
- — C (S) $13653
- — Z (S) $13653
1910.212 A01
- Issued
- Aug 13, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Line 11 - On or about March 24, 2021, the employer failed to ensure that hazards created by in running nip points on the Line 11 Full Case Incline Conveyor were guarded to prevent injury to employees while employees accessed the area to unjam boxes on the conveyor line. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Aug 13, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $9,753 · Current $9,753
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Line 11 - On or about March 18, 2021, employer failed to ensure that all pulleys within seven or less feet from working platforms on Line 11 Full Case Conveyor Line, Area B144, were provided with a guard on all exposed sides. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (O) $9753
- — C (S) $9753
- — Z (S) $9753
1910.219 E02 I
- Issued
- Aug 13, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(2)(i): Overhead horizontal belt(s) with lower parts seven -7 feet or less from the floor(s) or platform(s) were not guarded on the sides and bottom in accordance with the requirements specified at CFR 1910.219(o)(3): a) Line 11 - On or about March 18, 2021, employer failed to ensure that all belts within seven or less feet from working platforms on Line 11 Full Case Conveyor Line, Area B144, were provided with a guard on all exposed sides. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections at Fervalue USA INC. DBA Ferrero U.S.A., INC.
View Fervalue USA INC. DBA Ferrero U.S.A., INC.'s full OSHA safety record →