OKLAHOMA CITY, OK —
OSHA Inspection: STANDARD IRON & METAL CO., LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STANDARD IRON & METAL CO., LLC in 1501 EAST RENO AVENUE, OKLAHOMA CITY, OK 73117 (NAICS 423930). OSHA activity number 345197412.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STANDARD IRON & METAL CO., LLC
- Site address
- 1501 EAST RENO AVENUE
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73117
- Mailing
- 1501 EAST RENO AVENUE, OKLAHOMA CITY, OK 73117
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 40
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.101 B
- Issued
- Aug 27, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $5,461 · Current $2,730 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: On or about March 15, 2021, at the yard, a two compressed gas cylinders were stored piled with other metals, were not protected from damage, and exposed employees to fire hazards.
Recent events (2)
- — I (S) $2730
- — Z (S) $5461
1910.110 B09 II
- Issued
- Aug 27, 2021
- Penalty
- Initial $6,827 · Current $3,413 Reduced
General-duty citation text
29 CFR 1910.110(b)(9)(ii): Hose subject to container pressure was not marked "LP-Gas" or "LPG" at not greater than 10-foot intervals. On or about March 12, 2021 and at times prior, at a trailer at the torch cutting yard, the hose that connected a heater and a liquified petroleum compressed gas (propane) cylinder was not marked "LP-Gas" or "LPG" at not greater than 10-foot intervals and exposed employees to fire hazards.
Recent events (2)
- — I (S) $3413
- — Z (S) $6827
1910.110 B09 VII B
- Issued
- Aug 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(b)(9)(vii)(b): For use inside buildings the hose was not of minimum practical length, but exceeded 6 feet except as provided in paragraph (c)(5)(i)(g) of this section and extended from one room to another, or passed through any walls, partitions, ceilings, or floors. Such hose was concealed from view or used in a concealed location. For use outside of buildings, the hose may exceed this length but was not kept as short as practical. On or about March 12, 2021 and at times prior, at a trailer at the torch cutting yard, the hose that connected a heater and a liquified petroleum compressed gas (propane) cylinder was concealed below the trailer floor. The hose passed through a floor opening to the outside of the trailer and exposed employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 E05 V
- Issued
- Aug 27, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(e)(5)(v): Hose showing leaks, burns, worn places, or other defects rendering it unfit for service were not repaired or replaced: On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, hose for propane had worn places and was not repaired or replaced. Employees were exposed to fire hazards during oxygen and propane torch cutting operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.110 B20 I
- Issued
- Aug 27, 2021
- Abate by
- Sep 9, 2021
- Penalty
- Initial $6,827 · Current $3,413 Reduced
General-duty citation text
29 CFR 1910.110(b)(20)(i): Except as provided in paragraph (b)(20)(ii) of this section, new commercial and industrial gas consuming appliances were not approved. a. On or about March 12, 2021 and at times prior, in a trailer at the torch cutting yard, a heater was not approved and was fueled by a liquified petroleum compressed gas (propane) cylinder and exposed employees to fire hazards. b. On or about March 31, 2021 and at times prior, in the parts shack, a 55 gallon metal heater-barrel was not approved and was fueled by liquified petroleum compressed gas (propane) piping and exposed employees to fire hazards.
Recent events (2)
- — I (S) $3413
- — Z (S) $6827
1910.253 A04
- Issued
- Aug 27, 2021
- Abate by
- Dec 15, 2021
- Penalty
- Initial $9,557 · Current $4,778 Reduced
General-duty citation text
29 CFR 1910.253(a)(4): Rules and instructions covering the operations and maintenance of oxygen or fuel gas supply equipment including generators, and oxygen or fuel gas distribution piping systems were not readily available: On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, there were no readily available rules and instructions covering the operation and maintenance of oxygen distribution system. This exposed employees to a fire and explosion hazard.
Recent events (2)
- — I (S) $4778
- — Z (S) $9557
1910.253 D01 II C
- Issued
- Aug 27, 2021
- Abate by
- Nov 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(d)(1)(ii)(C): A pressure regulating device was not used at each station outlet when the connected equipment was used at pressure less than 250 psig (1.7 MPa): On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, pressure regulating devices were not used at 3 of 6 station outlets of the oxygen manifold where cutting torch hoses were connected and the supplied oxygen pressure was less than 250 psig. Employees were exposed to fire hazards during torch cutting operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B01 II
- Issued
- Aug 27, 2021
- Abate by
- Oct 18, 2021
- Penalty
- Initial $6,827 · Current $3,413 Reduced
General-duty citation text
29 CFR 1910.253(b)(1)(ii): Compressed gas cylinders were not legibly marked, for the purpose of identifying the gas content, with either the chemical or the trade name of the gas: On or about March 12, 2021 and at times prior, at a metal closet in front of the shredder machine, a liquified petroleum compressed gas cylinder was not legibly marked, for the purpose of identifying the gas content, with either the chemical or the trade name of the gas. Employees were exposed to fire hazards during oxygen and propane torch cutting operations.
Recent events (2)
- — I (O) $3413
- — Z (S) $6827
1910.1200 F10
- Issued
- Aug 27, 2021
- Abate by
- Oct 18, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were legible, in English and prominently displaced on the container or readily available in the work area throughout each work shift: a. On or about March 12, 2021 and at times prior, at a metal closet in front of the shredder machine, a liquified petroleum compressed gas (propane) cylinder was not legibly marked for hazard warnings and exposed employees to fire hazards. b. On or about March 12, 2021 and at times prior, at the yard for torch cutting metal, 3 liquified petroleum compressed gas (propane) cylinders were not legibly marked hazard warnings and exposed employees to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Aug 27, 2021
- Penalty
- Initial $6,827 · Current $3,413 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about March 12, 2021 and at times prior, at the metal sorting line, three stored cylinders of compressed oxygen were not separated from a stored liquified petroleum gas cylinder a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Employees used oxygen and liquified petroleum gas cylinders for torch cutting and were exposed to fire hazards.
Recent events (2)
- — I (S) $3413
- — Z (S) $6827
1910.253 B04 IV
- Issued
- Aug 27, 2021
- Abate by
- Oct 18, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iv): The employer did not comply with the provisions of the Standard for Bulk Oxygen Systems at Consumer Sites, NFPA No. 566-1965, as specified in this standard for liquid oxygen storage, where a liquid oxygen system was used to supply gaseous oxygen for welding or cutting operations: On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, employees used oxygen for torch cutting metal and the employer did not comply with the provisions of the Standard for Bulk Oxygen Systems at Consumer Sites, NFPA No. 566-1965. This exposed the employees to a fire hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 C03 V
- Issued
- Aug 27, 2021
- Abate by
- Oct 18, 2021
- Penalty
- Initial $6,827 · Current $3,413 Reduced
General-duty citation text
29 CFR 1910.253(c)(3)(v): The Low-Pressure Manifold, Do Not Connect High-Pressure Cylinders, and Maximum Pressure-250 psig (1.7 MPa) signs were not conspicuously posted at each manifold: On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, the employer did not ensure that the signs Low-Pressure Manifold, Do Not Connect High-Pressure Cylinders, and Maximum Pressure-250 psig (1.7 MPa) were conspicuously posted at the oxygen manifold. Employees were exposed to fire hazards during torch cutting operations.
Recent events (2)
- — I (S) $3413
- — Z (S) $6827
1910.253 D04 II
- Issued
- Aug 27, 2021
- Abate by
- Oct 18, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(d)(4)(ii): Aboveground piping systems were not marked in accordance with the American National Standard Scheme for the Identification of Piping Systems, ANSI A13.1 1956: On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, aboveground oxygen piping was not marked for oxygen. Employees were exposed to fire hazards during torch cutting operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 D04 III
- Issued
- Aug 27, 2021
- Abate by
- Oct 18, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(d)(4)(iii): Station outlets were not marked to indicate the name of the gas: On or about March 31, 2021 and at times prior, at the yard for torch cutting metal, station outlets of the oxygen manifold, where cutting torch hoses were connected, were not marked for oxygen. Employees were exposed to fire hazards during torch cutting operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Standard Iron & Metal CO., LLC
View Standard Iron & Metal CO., LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345197412.