Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CREDENCE CLEARWATER INDUSTRIAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CREDENCE CLEARWATER INDUSTRIAL, INC. in 900 7TH AVE NORTH, LEWISTON, ID 83501 (NAICS 561790). OSHA activity number 345197719.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Credence Clearwater Industrial, INC. — free Get an email when a new federal OSHA severe-injury report for Credence Clearwater Industrial, INC. is published. One employer, no account, unsubscribe in one click.
Site address
900 7TH AVE NORTH
City
LEWISTON
State
ID
ZIP
83501
Mailing
3900 INDUSTRIAL WAY, LEWISTON, ID 83501
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.1203 D

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $2,341 · Current $0 Reduced
29 CFR  1926.1203(d): After determining that employees it directs will enter a permit space, the employer did not have a written permit space program that complies with 29 CFR 1926.1204 implemented at the construction site:    a) Digester tank #3: On March 9, 2021 and at times prior thereto the employer, Credence Clearwater Industrial, had not developed and implemented their own confined space program for the protection of, and review by, their employees who enter and work in confined spaces at host employer and controlling employer jobsites.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2341

1926.1204 E01 II

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $0 · Current $2,341
29 CFR 1926.1204(e)(1)(ii): When entry was authorized, continuous monitoring of entry conditions in the areas where authorized entrants were working, was not done:  a) Digester tank #3: On March 9, 2021 and at times prior thereto employees performed cleaning activities in a 34 foot high, 50 foot diameter waste water treatment digester tank.  A single Honeywell Gas Alert MAX XTII monitor was used for continuous air monitoring.  It was located approximately 15 feet above the area where the authorized entrants were working.   Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (O) $2341
  • — Z (S) $0

1926.1205 F

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.1205(f): The entry employer did not retain each canceled entry permit for at least 1 year in order to facilitate a review of a permit-required confined space program required by �1926.1204(n):  a) On March 9, 2021 and at times prior thereto the employer did not acquire or maintain cancelled confined space entry permits from the host or controlling employer's they had worked with, as part of a permit -required confined space program, and in order to review any problems noted during the entry so corrective actions could be taken if needed to ensure the safety and health of their employees.  Credence Clearwater Industrial employees entered and performed sludge removal activities in a waste water treatment digester tank under a confined space entry permit generated and maintained by the controlling employer.     Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1207 A

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.1207(a): The employer did not provide training to each employee whose work is regulated by this standard, at no cost to the employee, to ensure that the employee possessed the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this standard. This training must result in an understanding of the hazards in the permit space and the methods used to isolate, control or in other ways protect employees from these hazards, and for those employees not authorized to perform entry rescues, in the dangers of attempting such rescue  a) On March 9, 2021 and at times prior thereto the employer had not developed or implemented their own employee training program for confined space, permit required confined space, and confined space entry.  The employer did not provide training for their employees that could then be supplemented, as needed, by a host or controlling employer to identify specific hazards and control methods unique to the jobsite and space being entered.  Employees performed sludge removal activities in a waste water treatment digester tank.    Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345197719.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.