Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE POOLE AND KENT COMPANY

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of THE POOLE AND KENT COMPANY in 7471 BEAR WALLOW ROAD, WARRENTON, VA 20186 (NAICS 238220). OSHA activity number 345206999.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Poole and Kent Company — free Get an email when a new federal OSHA severe-injury report for The Poole and Kent Company is published. One employer, no account, unsubscribe in one click.
Site address
7471 BEAR WALLOW ROAD
City
WARRENTON
State
VA
ZIP
20186
Mailing
4530 HOLLINS FERRY RD., BALTIMORE, MD 21227
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.350 A01

Other-than-serious Gravity 5 2 instances 3 exposed
Issued
May 10, 2021
Abate by
Jun 4, 2021
Penalty
Initial $7,022 · Current $4,915 Reduced
29 CFR  1926.350(a)(1):Valve protection cap(s) were not in place on compressed gas cylinder(s):  a)	Warrenton Army Training Center: On or about 03/19/2021, a nitrogen cylinder used for burning pipe was stored on a cart without a valve protection cap.   b)	Warrenton Army Training Center: On or about 03/19/2021, a nitrogen cylinder used for burning pipe was stored in a cylinder cage without a valve protection cap.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $4915.4
  • — Z (S) $7022

1926.501 B10

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2021
Abate by
Jun 4, 2021
Penalty
Initial $8,778 · Current $6,145 Reduced
29 CFR  1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:   a)	Warrenton Army Training Center: On or about 03/19/2021, fall protection was not provided for employees working on the roof HVAC units, as a result employees were exposed to a 13' fall hazard.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $6144.6
  • — Z (S) $8778

1926.502 D15

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2021
Abate by
Jun 4, 2021
Penalty
Initial $8,778 · Current $6,145 Reduced
29 CFR  1926.502(d)(15):Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:   a)	Warrenton Army Training Center: On or about 03/10/2021, employees attached their lanyard to the base of a HVAC unit that was not designed as an anchor point capable of supporting at least 5,000 pounds.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $6144.6
  • — Z (S) $8778

View The Poole and Kent Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345206999.