OSHA Inspection: HOME DEPOT U.S.A., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HOME DEPOT U.S.A., INC. in 820 BLOOMINGTON ROAD, CHAMPAIGN, IL 61820 (NAICS 444110). OSHA activity number 345223309.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Home Depot U.S.A., INC. — free Get an email when a new federal OSHA severe-injury report for Home Depot U.S.A., INC. is published. One employer, no account, unsubscribe in one click.
Site address
820 BLOOMINGTON ROAD
City
CHAMPAIGN
State
IL
ZIP
61820
Mailing
820 BLOOMINGTON ROAD, CHAMPAIGN, IL 61820
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
79
Ownership type
A

6 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2021
Penalty
Initial $12,873 · Current $7,724 Reduced
29 CFR  1910.22(a)(2):  Floor(s) of workroom (s) were not maintained in a clean and, so far as possible , a dry condition:  On or about March 26, 2021, employees were exposed to slipping and falling on the concrete floor in the receiving area because  of a damaged garage door that allowed the accumulation of rain water on the floor.
Recent events (2)
  • — I (S) $7723.8
  • — Z (S) $12873

1910.22 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2021
Penalty
Initial $12,873 · Current $7,724 Reduced
29 CFR  1910.22(a)(3): Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  On or about, March 26, 2021, employees were exposed to trip and fall hazards while working from the order picker because the corner of the platform was damaged and not secure.
Recent events (2)
  • — I (S) $7723.8
  • — Z (S) $12873

1910.28 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 3, 2021
Abate by
Sep 15, 2021
Penalty
Initial $13,653 · Current $8,192 Reduced
29 CFR  1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4-feet (1.2 m) or more above a lower level is protected from falling by a guardrail system, safety net system, or personal fall protection system:  On or about March 24, 2021, an employee was exposed to a fall hazard up to 10 feet while working from an order picker platform because the employer did not ensure fall protection was used.
Recent events (2)
  • — I (S) $8191.8
  • — Z (S) $13653

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 3, 2021
Penalty
Initial $6,436 · Current $3,862 Reduced
29 CFR  1910.303(b)(2): Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling:  On or about March 26, 2021, employees were exposed to electrical hazards in the entrance area of the store because a relocatable power tap was series connected to an extension cord.
Recent events (2)
  • — I (S) $3861.6
  • — Z (S) $6436

1910.305 B01 II

Serious Gravity 1 2 instances 3 exposed
Issued
Sep 3, 2021
Penalty
Initial $6,436 · Current $3,862 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed:  On or about March 26, 2021, employees were exposed to electrical hazards because there were unused openings on the electrical box at the following locations:  a.	Electrical box in the break room  b.	Electrical box in the conference room
Recent events (2)
  • — I (S) $3861.6
  • — Z (S) $6436

1910.305 G01 IV D

Serious Gravity 1 2 instances 3 exposed
Issued
Sep 3, 2021
Penalty
Initial $6,436 · Current $3,862 Reduced
29 CFR  1910.305(g)(1)(iv)(D): Flexible cords and/or cables were attached to building surfaces:  a.   On or about March 26, 2021, employees in the entryway area to the store were exposed to electrical and trip hazards because a white extension cord was stapled to the wall and then connected to a relocatable power tap lying on the ground.  b.	On or about March 26, 2021, employees in the entryway area to the store were exposed to electrical and trip hazards because a black electrical cord exiting the electrical box was stapled to the wall and then connected to a relocatable power tap lying on the ground.
Recent events (2)
  • — I (S) $3861.6
  • — Z (S) $6436

View Home Depot U.S.A., INC.'s full OSHA safety record →