DUTCH HARBOR, AK —
OSHA Inspection: CMA TERMINALS ALASKA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CMA TERMINALS ALASKA in 1125 EAST POINT ROAD, DUTCH HARBOR, AK 99692 (NAICS 488510). OSHA activity number 345227870.
Where did this inspection happen?
- Establishment
- CMA TERMINALS ALASKA
- Site address
- 1125 EAST POINT ROAD
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- 1125 EAST POINT ROAD, DUTCH HARBOR, AK 99692
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488510
- Employees
- 36
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $7802.00 · Current $5461.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Fabrication Shop - On or about March 31, 2021, employees used a 120V AC Tri-Tap Connector (model 6yF68) with an SJTW 14/3 extension cord to energize lighting, battery charging station, and portable hand tools. The end plug was series chained to another extension cord and was not directly plugged into a receptacle in accordance with manufacturer instruction and the UL labeling requirements, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $5461
- — Z (S) $7802
1910.303 G01 I C
- Issued
- Abate by
- Penalty
- Initial $9753.00 · Current $6827.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303: a) Electrical Room - On or about March 31, 2021, the working space in front of a three-phase 120 volt panel labeled Panel CR-1, had a garbage can and five (5) gallon bucket in front of it, exposing employees to electrical and fire hazards. b) Electrical Room - On or about March 31, 2021, the working space in front of a 480 volt distribution panelboard labeled T1-2-3, had a desk, computer chair, letter storage, and energy control locks and tags in front of it, exposing employees to electrical and fire hazards. c) Electrical Room - On or about March 31, 2021, the working space in front of 240 volt panel labeled WP-2 had a box and garbage can in front of it, exposing employees to electrical and fire hazards. d) Fabrication Shop - On or about March 31, 2021, the working space in front of a breaker panel N had a Smartwasher parts washer in front of it, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $6827
- — Z (S) $9753
1910.305 G01 IV
- Issued
- Abate by
- Penalty
- Initial $11703.00 · Current $8192.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv):Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): a) Powerhouse - On or about March 31, 2021, a flexible extension cord was placed through a hole in the wall and used as a means of fixed wiring to provide power to computer equipment, exposing employees to electrical and fire hazards. b) Powerhouse - On or about March 31, 2021, a flexible cord was used as a substitute for fixed wiring to energize a 120V SIMPLX packaged pump set (model: SPS-20). The flexible cord was painted with white paint and placed behind metal brackets attached to the wall and through holes in the ceiling area, exposing employees to electrical and fire hazards. c) Fabrication Shop - On or about March 31, 2021, a flexible cord of a LumaPro 50 ft. tri-tap cord reel (model 6YF68) was used as a substitute for fixed wiring to energize lighting, battery charging station, and powered hand tools. The flexible cord was placed through and concealed in a wall and door opening. These conditions exposed employees to electrical and fire hazards. d) Fabrication Shop - On or about March 31, 2021, a flexible red extension cord was used as a substitute for fixed wiring to energize a refrigerator. The extension cord was attached to the walls with metal bracing and nails, exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $8192
- — Z (S) $11703
1917.95 C
- Issued
- Abate by
- Penalty
- Initial $7802.00 · Current $5461.00 Reduced
General-duty citation text
29 CFR 1917.95(c):The employer did not provide well maintained emergency bathing, eye washing or other facilities where employees were exposed to hazardous substances. a) Top Pick Shed - On or about March 31, 2021, employees were provided a Honeywell PortaStream II Emergency Eyewash Station (SN: 616988) to flush eyes in the event of an emergency. The eyewash saline solution was not maintained in accordance with manufacturer requirements, exposing employees to biological hazards. b) Powerhouse - On or about March 31, 2021, employees were provided a Sperian Fendall Flash Flood Catridge emergency eyewash station (SN: 414171) to flush eyes in the event of an emergency. The eyewash saline solution was not maintained in accordance with manufacturer requirements, exposing employees to biological hazards. c) Fabrication Shop - On or about March 31, 2021, employees handled and transferred corrosive materials including, but not limited to Sodium Metasilicate and Skyko Oshpho Rust Treatment, and were not provided a suitable eyewash station in that it was not inspected and maintained, exposing employees to biological hazards.
Recent events (2)
- — I (S) $5461
- — Z (S) $7802
1917.112 B01
- Issued
- Abate by
- Penalty
- Initial $9753.00 · Current $6827.00 Reduced
General-duty citation text
29 CFR 1917.112(b)(1): Guardrails were not provided at locations where employees were exposed to floor or wall openings or waterside edges, including bridges or gangway-like structures leading to pilings or vessel mooring or berthing installations, which presented a hazard of falling more than 4 feet or into the water.: a) Top Pick Shed - On or about March 31, 2021, employees walked and worked performing maintenance on top picks from the second floor level, without guardrails and were exposed to falls of approximately 9 1/2 feet to the concrete floor below.
Recent events (2)
- — I (S) $6827
- — Z (S) $9753
1917.151 B01
- Issued
- Abate by
- Penalty
- Initial $7802.00 · Current $5461.00 Reduced
General-duty citation text
29 CFR 1917.151(b)(1): Danger zones on machines and equipment used by employees were not guarded. a) Top Pick Shed - On or about March 31, 2021, employees operated a 15 inch bench drill press manufactured by Jet (Model: J-2530, S/N: 354401) unguarded at the point of operation, exposing employees to caught-in hazards. b) Fabrication Shop - On or about March 31, 2021, employees operated a 20 inch bench drill press manufactured by Dayton unguarded at the point of operation, exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $5461
- — Z (S) $7802
1904.32 A01
- Issued
- Abate by
- Penalty
- Initial $1951.00 · Current $975.00 Reduced
General-duty citation text
29 CFR 1904.32(a)(1): A review of the OSHA Log of Recordable Work-Related Injuries and Illnesses (OSHA Form 300 or equivalent) was not completed to ensure the Log was accurate and complete, and/or deficiencies were not identified and corrected at the end of each calendar year. a) 1125 East Point Road - On or about March 31, 2021, the employer had provided an OSHA 300A annual summary for calendar year 2018, but the annual summary was not completed in detail with 11 injuries not recorded onto the annual summary from the OSHA 300 Injury and Illness Log. The annual review conducted by the terminal manager also failed to identify missing information on the 2018 OSHA 300 Log with the following fields not captured; G, H, I, J, K, L, and M.
Recent events (2)
- — I (O) $975
- — Z (O) $1951
1917.111 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1917.111(d): All walking and working surfaces in the terminal areas were not maintained in good repair.: a) Powerhouse/Engine Room - On or about March 31, 2021, employees performed repairs and maintenance in the engine room. A four (4) inch diameter drain hole was observed in the floor area without a guard, exposing employees to tripping hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CMA TERMINALS ALASKA
DUTCH HARBOR, AK—2024-02-13 00:00:00
CMA TERMINALS ALASKA
DUTCH HARBOR, AK—2024-02-13 00:00:00
CMA TERMINALS ALASKA
DUTCH HARBOR, AK—2022-03-24 00:00:00
CMA TERMINALS ALASKA
DUTCH HARBOR, AK—2022-03-24 00:00:00
CMA TERMINALS ALASKA
DUTCH HARBOR, AK—2021-03-31 00:00:00
CMA TERMINALS ALASKA
View CMA TERMINALS ALASKA's full OSHA safety record →
More inspections in this industry (NAICS 488510)
FRESNO, CA—2026-07-08
GXO
STOCKTON, CA—2026-07-08
RTW LOGISTICS INC.
PICO RIVERA, CA—2026-06-26
ESTES FORWARDING WORLDWIDE
RENO, NV—2026-06-23
3T LOGISTICS LLC
ELK GROVE VILLAGE, IL—2026-06-18
MORAN TRANSPORTATION CORP
More inspections in AK
ANCHORAGE, AK—2026-07-10
AK, INC
ANCHORAGE, AK—2026-07-08
ONE STOP SERVICES
, AK—2026-07-08
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345227870.