OSHA Inspection: CMA TERMINALS ALASKA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CMA TERMINALS ALASKA in 1125 EAST POINT ROAD, DUTCH HARBOR, AK 99692 (NAICS 488510). OSHA activity number 345227870.

Watch CMA Terminals Alaska — free Get an email when a new federal OSHA severe-injury report for CMA Terminals Alaska is published. One employer, no account, unsubscribe in one click.
Site address
1125 EAST POINT ROAD
City
DUTCH HARBOR
State
AK
ZIP
99692
Mailing
1125 EAST POINT ROAD, DUTCH HARBOR, AK 99692
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488510
Employees
36
Ownership type
A

8 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5461.00 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Fabrication Shop - On or about March 31, 2021, employees used a 120V AC Tri-Tap Connector (model 6yF68) with an SJTW 14/3 extension cord to energize lighting, battery charging station, and portable hand tools.  The end plug was series chained to another extension cord and was not directly plugged into a receptacle in accordance with manufacturer instruction and the UL labeling requirements, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $5461
  • — Z (S) $7802

1910.303 G01 I C

Serious Gravity 5 4 instances 23 exposed
Issued
Abate by
Penalty
Initial $9753.00 · Current $6827.00 Reduced
29 CFR  1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303:   a) Electrical Room - On or about March 31, 2021, the working space in front of a three-phase 120 volt panel labeled Panel CR-1, had a garbage can and five (5) gallon bucket in front of it, exposing employees to electrical and fire hazards.  b) Electrical Room - On or about March 31, 2021, the working space in front of a 480 volt distribution panelboard labeled T1-2-3, had a desk, computer chair, letter storage, and energy control locks and tags in front of it, exposing employees to electrical and fire hazards.  c) Electrical Room - On or about March 31, 2021, the working space in front of 240 volt panel labeled WP-2 had a box and garbage can in front of it, exposing employees to electrical and fire hazards.  d) Fabrication Shop - On or about March 31, 2021, the working space in front of a breaker panel N had a Smartwasher parts washer in front of it, exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $6827
  • — Z (S) $9753

1910.305 G01 IV

Serious Gravity 5 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $11703.00 · Current $8192.00 Reduced
29 CFR  1910.305(g)(1)(iv):Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a):  a) Powerhouse - On or about March 31, 2021, a flexible extension cord was placed through a hole in the wall and used as a means of fixed wiring to provide power to computer equipment, exposing employees to electrical and fire hazards.  b) Powerhouse - On or about March 31, 2021, a flexible cord was  used as a substitute for fixed wiring to energize a 120V SIMPLX packaged pump set (model: SPS-20).  The flexible cord was painted with white paint and placed behind metal brackets attached to the wall and through holes in the ceiling area, exposing employees to electrical and fire hazards.  c) Fabrication Shop - On or about March 31, 2021, a flexible cord of a LumaPro 50 ft. tri-tap cord reel (model 6YF68) was used as a substitute for fixed wiring to energize lighting, battery charging station, and powered hand tools.  The flexible cord was placed through and concealed in a wall and door opening.  These conditions exposed employees to electrical and fire hazards.  d) Fabrication Shop - On or about March 31, 2021, a flexible red extension cord was used as a substitute for fixed wiring to energize a refrigerator.  The extension cord was attached to the walls with metal bracing and nails, exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $8192
  • — Z (S) $11703

1917.95 C

Serious Gravity 5 2 instances 23 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5461.00 Reduced
29 CFR  1917.95(c):The employer did not provide well maintained emergency bathing, eye washing or other facilities where employees were exposed to hazardous substances.  a) Top Pick Shed - On or about March 31, 2021,  employees were provided a Honeywell PortaStream II Emergency Eyewash Station (SN: 616988) to flush eyes in the event of an emergency.  The eyewash saline solution was not maintained in accordance with manufacturer requirements, exposing employees to biological hazards.  b) Powerhouse - On or about March 31, 2021,  employees were provided a Sperian Fendall Flash Flood Catridge emergency eyewash station (SN: 414171)  to flush eyes in the event of an emergency.  The eyewash saline solution was not maintained in accordance with manufacturer requirements, exposing employees to biological hazards.  c) Fabrication Shop - On or about March 31, 2021, employees handled and transferred corrosive materials including, but not limited to Sodium Metasilicate and Skyko Oshpho Rust Treatment, and were not provided a suitable eyewash station in that it was not inspected and maintained, exposing employees to biological hazards.
Recent events (2)
  • — I (S) $5461
  • — Z (S) $7802

1917.112 B01

Serious Gravity 5 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $9753.00 · Current $6827.00 Reduced
29 CFR  1917.112(b)(1):  Guardrails were not provided at locations where employees were exposed to floor or wall openings or waterside edges, including bridges or gangway-like structures leading to pilings or vessel mooring or berthing installations, which presented a hazard of falling more than 4 feet or into the water.:  a) Top Pick Shed - On or about March 31, 2021, employees walked and worked performing maintenance on top picks from the second floor level, without guardrails and were exposed to falls of approximately 9 1/2 feet to the concrete floor below.
Recent events (2)
  • — I (S) $6827
  • — Z (S) $9753

1917.151 B01

Serious Gravity 5 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5461.00 Reduced
29 CFR  1917.151(b)(1): Danger zones on machines and equipment used by employees were not guarded.  a) Top Pick Shed - On or about March 31, 2021, employees operated a 15 inch bench drill press manufactured by Jet (Model: J-2530, S/N: 354401) unguarded at the point of operation, exposing employees to caught-in hazards.  b) Fabrication Shop - On or about March 31, 2021, employees operated a 20 inch bench drill press manufactured by Dayton unguarded at the point of operation, exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $5461
  • — Z (S) $7802

1904.32 A01

Other-than-serious 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $1951.00 · Current $975.00 Reduced
29 CFR  1904.32(a)(1): A review of the OSHA Log of Recordable Work-Related Injuries and Illnesses (OSHA Form 300 or equivalent) was not completed to ensure the Log was accurate and complete, and/or deficiencies were not identified and corrected at the end of each calendar year.  a) 1125 East Point Road - On or about March 31, 2021, the employer had provided an OSHA 300A annual summary for calendar year 2018, but the annual summary was not completed in detail with 11 injuries not recorded onto the annual summary from the OSHA 300 Injury and Illness Log.  The annual review conducted by the terminal manager also failed to identify missing information on the 2018 OSHA 300 Log with the following fields not captured; G, H, I, J, K, L, and M.
Recent events (2)
  • — I (O) $975
  • — Z (O) $1951

1917.111 D

Other-than-serious 1 instance 23 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1917.111(d):   All walking and working surfaces in the terminal areas were not maintained in good repair.:  a) Powerhouse/Engine Room - On or about March 31, 2021, employees performed repairs and maintenance in the engine room.  A four (4) inch diameter drain hole was observed in the floor area without a guard, exposing employees to tripping hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CMA TERMINALS ALASKA's full OSHA safety record →