WALSENBURG, CO —
OSHA Inspection: J. M. TIRE INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J. M. TIRE INC in 928 MAIN ST, WALSENBURG, CO 81089 (NAICS 441320). OSHA activity number 345230239.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. M. TIRE INC
- Site address
- 928 MAIN ST
- City
- WALSENBURG
- State
- CO
- ZIP
- 81089
- Mailing
- 709 N. COMMERCIAL, TRINIDAD, CO 81082
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441320
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- May 3, 2021
- Abate by
- Jun 30, 2021
- Penalty
- Initial $6,827 · Current $3,414 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees where employees were exposed to crushing and struck-by hazards when using the AMMCO automotive lift model number B2900, serial number P970825854: a) On or about April 1, 2021, and at times prior, the employer continued to operate and allow employees to operate an automotive lift without performing an inspection to identify a missing safety device and remove the item from service until replacement parts were installed. The AMMCO two-pole automotive lift was designed to have an up-limit switch spanning the length of and under the steel cross-member; this lift was missing the up-limit switch. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $3413.5
- — Z (S) $6827
1910.28 B01 I
- Issued
- May 3, 2021
- Abate by
- Aug 2, 2021
- Penalty
- Initial $6,827 · Current $3,414 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) On or about April 1, 2021, and at times prior, the employer exposed workers to falling thirteen feet to the shop floor from the unguarded north and south edges of a mezzanine above the shop floor. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $3413.5
- — Z (S) $6827
1910.29 F04
- Issued
- May 3, 2021
- Abate by
- Aug 2, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(f)(4): Openings in stair rails. An opening in a stair rail system exceeded 19 inches at its least dimension: a) On or about April 1, 2021, and at times prior, the employer exposed workers to falling from a stair system that ascended thirteen feet from the shop floor to the mezzanine level that had a twenty-five inch opening due to a missing mid rail. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- May 3, 2021
- Abate by
- May 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about April 1, 2021, and at times prior, the employer exposed workers to fire hazards in that the fire extinguisher was placed on a wall behind a tire repair device which diminished readily available access. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B07 IV
- Issued
- May 3, 2021
- Abate by
- May 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): 29 CFR 1910.303(b)(7)(iv): Employer did not ensure that there were no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:: a)Shop: On or about April 1, 2021 and at times prior, the employer exposed workers to electrical hazards in that an outlet faceplate was damaged with part of the cover missing. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).