NORFOLK, VA —
OSHA Inspection: USS MCFAUL DDG 74
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of USS MCFAUL DDG 74 in ONBOARD USS MCFAUL (DDG 74) @ GD NASSCO - 200 LIGON ST., NORFOLK, VA 23523 (NAICS 928110). OSHA activity number 345233738.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- USS MCFAUL DDG 74
- Site address
- ONBOARD USS MCFAUL (DDG 74) @ GD NASSCO - 200 LIGON ST.
- City
- NORFOLK
- State
- VA
- ZIP
- 23523
- Mailing
- 1751 MORRIS STREET COMMANDER, NAVAL SURFACE FORCE ATLANTIC, NORFOLK, VA 23511
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 400
- Ownership type
- D
Citations
4 citations on file for this inspection.
1915.89 C01
- Issued
- Sep 15, 2021
- Abate by
- Oct 12, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.89(c)(1):The employer did not ensure that, before any authorized employee performed servicing when energization or startup, or the release of hazardous energy, may occur, all energy sources were identified and isolated, and the machinery, equipment, or system was rendered inoperative. On or about 03-15-2021, and times prior thereto, onboard the USS McFaul, DDG-74, located at General Dynamics - NASSCO Norfolk 200 Ligon Street. Norfolk, VA 23523: Employee(s) were exposed to pinch point and crushing hazards from a gas turbine engine blow-in door that was tagged out in the open position and not de-pressurized, de-energized, restrained, or isolated from all energy sources of power. No other verification of additional safety measures necessary to provide the equivalent safety available from the use of a lock were implemented. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1915.89 C04 II
- Issued
- Sep 15, 2021
- Abate by
- Oct 12, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.89(c)(4)(ii):At least one additional safety measure that, along with the energy-isolating device and tag required in (c)(4)(i) of this section, did not provide the equivalent safety available from the use of a lock. Note to paragraph (c)(4) of this section: When the Navy ship's force maintains control of the machinery, equipment, or systems on a vessel and has implemented such additional measures it determines are necessary, the provisions of paragraph (c)(4)(ii) of this section shall not apply, provided that the employer complies with the verification procedures in paragraph (g) of this section. On or about 03-15-2021, and times prior thereto, onboard the USS McFaul, DDG-74 located at General Dynamics - NASSCO Norfolk 200 Ligon Street. Norfolk, VA 23523: Employee(s) were exposed to pinch point and crushing hazards from a gas turbine engine blow-in door that was tagged out in the open position and not de-pressurized, de-energized, restrained, or isolated from all energy sources of power. No additional safety measures and no other verification of additional safety measures necessary to provide the equivalent safety available from the use of a lock was implemented. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1915.89 G01
- Issued
- Sep 15, 2021
- Abate by
- Oct 12, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.89(g)(1): Before servicing machinery, equipment, or a system that had a lockout/tags-plus system, the employer did not ensure that the authorized employee, or the primary authorized employee in a group lockout/tags-plus application, verified that the machinery, equipment, or system was deenergized and all energy sources isolated. On or about 03-15-2021, and times prior thereto, onboard the USS McFaul, DDG-74 located at General Dynamics - NASSCO Norfolk 200 Ligon Street. Norfolk, VA 23523: Employee(s) were exposed to pinch point and crushing hazards from a gas turbine engine blow-in door that was tagged out in the "open" position and not de-pressurized, de-energized, restrained, or isolated from all energy sources of power. No other verification of additional safety measures necessary to provide the equivalent safety available from the use of a lock was implemented. The employer did not ensure that all sub-contractor employee(s) exposed to the caught-between hazard verified that the machinery, equipment, or system was deenergized and all energy sources were isolated. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1960.8 A
- Issued
- Sep 15, 2021
- Abate by
- Oct 4, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.8(a): The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm in that the Moisture Separator/Blow-in Panel Set three-position control switch was defective and allowed for the switch to be inadvertently turned without depressing it, subsequently resulting in the death of an employee from a caught-between hazard inside the closing area of the gas turbine inlet blow-in panel door. On or about 03-15-2021 and times prior thereto, onboard the USS McFaul, DDG-74 located at General Dynamics - NASSCO Norfolk 200 Ligon Street. Norfolk, VA 23523: the employer did not provide mechanically safe components located on shipboard system equipment that exposed employee(s) to pinch point and caught between hazards. Specifically, the three positions control switch located in the engine room that operated the Moisture Separator/Blow-in Panel Set was defective and did not operate as designed by the manufacturers technical manual S9234-GB-MMA-010/46219, 0910-LP-231-1900 . The control switch had three positions: AUTO, CLOSED, and OPEN and the switch must be depressed prior to changing its position to open or close the remote filter door set. This switch was defective and the required safety feature "Push to Turn" did not function, which allowed the switch to be turned freely, actuating the blow-in doors without pushing it inward to turn while the employee was inside the closure area of the filer panel blow-in door Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 928110)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345233738.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.