Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SINCLAIR & RUSH, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SINCLAIR & RUSH, INC. in 640 DELL ROAD, CARLSTADT, NJ 07072 (NAICS 326199). OSHA activity number 345234314.

Watch Sinclair & Rush, INC. — free Get an email when a new federal OSHA severe-injury report for Sinclair & Rush, INC. is published. One employer, no account, unsubscribe in one click.
Site address
640 DELL ROAD
City
CARLSTADT
State
NJ
ZIP
07072
Mailing
640 DELL ROAD, CARLSTADT, NJ 07072
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
70
Ownership type
A

12 citations on file for this inspection.

1910.22 A03

Serious Gravity 5 3 instances 2 exposed
Issued
Sep 24, 2021
Penalty
Initial $7,802 · Current $3,901 Reduced
29 CFR 1910.22(a)(3): (3) Walking-working surfaces are not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  a) Building Interior Injection molding area: Employees were exposed trips and slips fall hazards while working in the floor with oil spills on the floor surface, on or about  6/29/21.  b) Building Interior Injection molding area: Employees were exposed trips and slips fall hazards while working in the floor with oil spills on the floor surface, on or about 7/22/21.  c)  Building Interior Injection molding area: Employees were exposed trips and slips fall hazards while working in the floor with oil spills on the floor surface, on or about  8/4/21.
Recent events (2)
  • — I (S) $3901
  • — Z (S) $7802

1910.101 B

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 24, 2021
Abate by
Oct 21, 2021
Penalty
Initial $7,802 · Current $3,901 Reduced
29 CFR  1910.101(b):29 CFR 1910.253(b)(2)(ii): A storage location for welding or cutting gas cylinders was inadequate.  a) Maintenance  Shop:  Employees were storing welding and cutting gas cylinders that were not separated  when not in use in the maintenance shop, and they were not secure, on or about  8/4/21.
Recent events (2)
  • — I (S) $3901
  • — Z (S) $7802

1910.176 B

Serious Gravity 5 1 instance 315 exposed
Issued
Sep 24, 2021
Penalty
Initial $7,802 · Current $3,901 Reduced
29 CFR 1910.176(b): Storage of material created a hazard.  a) Building interior-Warehouse: Employees were exposed to struck-by hazards from stored materials that were kept on storage racks that were not secure, on or about  6/29/21
Recent events (2)
  • — I (S) $3901
  • — Z (S) $7802

1910.179 B08

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 24, 2021
Abate by
Oct 21, 2021
Penalty
Initial $7,802 · Current $3,901 Reduced
29 CFR  1910.179(b)(8):Only designated personnel shall be permitted to operate a crane covered by this section.  Injection molding area:  Non designated personnel were permitted to operate a crane, on or about 7/22/21 -
Recent events (2)
  • — I (S) $3901
  • — Z (S) $7802

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 24, 2021
Penalty
Initial $13,653 · Current $6,827 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, rotating parts:   a) Injection Molding Machine #9: An employee's  sustained burns to his right hand and face while using an injection molding machine without a guard, on or about 3/30/21.
Recent events (2)
  • — I (S) $6826.5
  • — Z (S) $13653

1910.212 B

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 24, 2021
Penalty
Initial $5,851 · Current $2,926 Reduced
29 CFR  1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.   a) Maintenance shop and warehouse: Employees were using grinders that were not secure to prevent excessive movement, on or about 8/4/21
Recent events (2)
  • — I (S) $2925.5
  • — Z (S) $5851

1910.215 A04

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 24, 2021
Penalty
Initial $5,851 · Current $2,926 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Building Interior-Maintenance Shop:  Employees were using a grinding machine that was not adjusted closely to the wheel with a maximum opening of one eighth of an inch, on or about 8/4/21  b) building interior warehouse:  Employees were using a grinding machine that was not adjusted closely to the wheel with a maximum opening of one eighth of an inch, on or about 8/4/21
Recent events (2)
  • — I (S) $2925.5
  • — Z (S) $5851

1910.215 B09

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 24, 2021
Penalty
Initial $5,851 · Current $2,926 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   a) Building interior Mechanic Shop:  Employees were using a grinding machine where the adjustable tongue or the end of the safety guard member at the top exceeded one fourth of an inch from the abrasive wheel, on or about 8/4/21.  b) ) Building interior warehouse:  Employees were using a grinding machine where the adjustable tongue or the end of the safety guard member at the top exceeded one fourth of an inch from the abrasive wheel, on or about 8/4/21.
Recent events (2)
  • — I (S) $2925.5
  • — Z (S) $5851

1910.303 F02

Serious Gravity 1 2 instances 315 exposed
Issued
Sep 24, 2021
Abate by
Oct 21, 2021
Penalty
Initial $5,851 · Current $2,926 Reduced
29 CFR  1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  a) Warehouse different locations: The panel box was not legibly marked to indicate its purpose of the circuit breakers, on or about 7/22/21.  b) Warehouse different locations: The panel box was not legibly marked to indicate its purpose of the circuit breakers, on or about 8/4/21.
Recent events (2)
  • — I (S) $2925.5
  • — Z (S) $5851

1910.303 G02 I

Serious Gravity 5 3 instances 5 exposed
Issued
Sep 24, 2021
Penalty
Initial $7,802 · Current $3,901 Reduced
29 CFR  1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) Injection molding machines #1, 3, 4. The electrical panel box cover for the injection molding  machines were open, exposing employees to electrical hazards, on or about 6/29/21.  b) Injection molding machines #1, 3, 4. The electrical panel box cover for the injection molding  machines were open, exposing employees to electrical hazards, on or about 7/22/21.  c)  Injection molding machines #1, 3, 4. The electrical panel box cover for the injection molding  machines were open, exposing employees to electrical hazards, on or about 8/4/21
Recent events (2)
  • — I (S) $3901
  • — Z (S) $7802

1910.304 F01 IV

Serious Gravity 5 3 instances 315 exposed
Issued
Sep 24, 2021
Penalty
Initial $11,703 · Current $5,852 Reduced
29 CFR  1910.304(f)(1)(iv): Over-current devices were not readily accessible to each employee or authorized building management personnel.   a) Warehouse Panel boxes different locations: Cardboard boxes, machinery , 55 gallons drums, machinery were stored in front of electrical panels, blocking access, on or about 6/29/21   b) Warehouse Panel boxes different locations: Cardboard boxes, machinery , 55 gallons drums, machinery were stored in front of electrical panels, blocking access, on or about 7/22/21  c) Warehouse Panel boxes different locations: Cardboard boxes, machinery , 55 gallons drums , machinery were stored in front of electrical panels, blocking access, on or about 8/4/21.
Recent events (2)
  • — I (S) $5851.5
  • — Z (S) $11703

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2021
Penalty
Initial $11,703 · Current $5,852 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) Building Interior:  Employee was exposed to an electrical shock while using an a commercial fan and the cord that was not grounded, on or about 8/4/21  b) Over Molding area:  Employees were exposed to electrical shocks while operating an excursion machine that was not properly grounded on or about 8/4/21.  c) assembly are:  Employees were exposed to electrical shock  while suing junction boxes that were not properly grounded in the assembly area, on or about 8/4/21.
Recent events (2)
  • — I (S) $5851.5
  • — Z (S) $11703

View Sinclair & Rush, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345234314.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.