Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GDTPT, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GDTPT, INC. in 1 PONDEROSA COURT, MONTROSE, CO 81401 (NAICS 333515). OSHA activity number 345234710.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gdtpt, INC. — free Get an email when a new federal OSHA severe-injury report for Gdtpt, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GDTPT, INC.
Site address
1 PONDEROSA COURT
City
MONTROSE
State
CO
ZIP
81401
Mailing
1 PONDEROSA COURT, MONTROSE, CO 81401
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333515
Employees
11
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 4 instances 1 exposed
Issued
May 7, 2021
Penalty
Initial $1,989 · Current $1,200 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Genham Diamond Tooling Systems at 1 Ponderosa Ct. Montrose, CO: On or before 4/6/21, the employer did not ensure that the Hardige HLVH manual lathe was equipped with a chip guard. This condition exposed employees to hot chips.  (b) Genham Diamond Tooling Systems at 1 Ponderosa Ct. Montrose, CO: On or before 4/6/21, the employer did not ensure that the Nardini-TT 1030E manual lathe was equipped with a chip guard. This condition exposed employees to hot chips.  (c) Genham Diamond Tooling Systems at 1 Ponderosa Ct. Montrose, CO: On or before 4/6/21, the employer did not ensure that the Alliant manual mill was equipped with a chip guard. This condition exposed employees to hot chips.  (d) Genham Diamond Tooling Systems at 1 Ponderosa Ct. Montrose, CO: On or before 4/6/21, the employer did not ensure that the Bridgeport/HH Roberts manual mill was equipped with a chip guard. This condition exposed employees to hot chips.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1989

1910.303 G01 II

Other-than-serious 1 instance 5 exposed
Issued
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   (a) Genham Diamond Tooling Systems at 1 Ponderosa Ct. Montrose, CO: On or before 4/6/21, the employer did not ensure that the space surrounding electrical service panels was at least 30 inches. Items were stored within this area. This condition exposed employees to electric shock and fire hazards.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345234710.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.