OSHA Inspection: HART RESTORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HART RESTORATION in 205 W 4TH STREET, CINCINNATI, OH 45202 (NAICS 238390). OSHA activity number 345242119.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hart Restoration — free Get an email when a new federal OSHA severe-injury report for Hart Restoration is published. One employer, no account, unsubscribe in one click.
Establishment
HART RESTORATION
Site address
205 W 4TH STREET
City
CINCINNATI
State
OH
ZIP
45202
Mailing
2530 SPRING GROVE AVENUE, CINCINNATI, OH 45214
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Oct 15, 2021
Penalty
Initial $4,096 · Current $4,000 Reduced
29 CFR  1926.20(b)(2): Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  a) On or about 04/08/2021, the competent person designated by the employer did not inspect the vertical and horizontal lifelines that were located on the roof. In addition the designated competent person did not had knowledge of the make, model and manufacture of the vertical and horizontal lifeline cable system being use to ensure capability.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4096

1926.502 D06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(6)(i): Fall protection systems criteria and practices. Personal fall arrest systems. Unless the snap-hook is a locking type and designed for the following connections, snap-hooks shall not be engaged: directly to webbing, rope or wire rope.  a)  On or about 04/08/2021, employees were connecting snap-hooks to be engaged directly to wire rope.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D08

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $4,096 · Current $0 Reduced
29 CFR  1926.502(d)(8):  Fall protection systems criteria and practices. Personal fall arrest systems.  Horizontal lifelines shall be designed, installed, and used, under the supervision of a qualified person, as part of a complete personal fall arrest system, which maintains a safety factor of at least two.    a) On or about 04/08/2021, while three employees were working from and descending from an electrical powered adjustable two point suspension scaffold system. The employer did not ensure that the horizontal and vertical lifelines were designed, installed and used, under the supervision of a qualified person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4096

1926.502 D20

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $4,096 · Current $0 Reduced
29 CFR  1926.502(d)(20):  Fall protection systems criteria and practices. Personal fall arrest systems.   The employer shall provide for prompt rescue of employees in the event of a fall or shall assure that employees are able to rescue themselves.   a) On or about 04/08/2021, while three employees were working from and descending from an electrical powered adjustable two point suspension scaffold system, there was no rescue plan established by the employer in case of a fall, accident, or incident.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4096

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $4,096 · Current $0 Reduced
29 CFR  1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  a) On or about 04/08/2021, each employee working from approximately 100 ft. from the ground, on an electrical powered adjustable two point suspension scaffold system while utilizing inadequate fall protection were not trained on the hazards of falling, and procedures to follow to minimized the hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4096

1926.451 F03

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $4,096 · Current $0 Reduced
29 CFR  1926.451(f)(3): Use. Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  a)  On or about 04/08/2021, while three employees were working from and descending from an electrical powered adjustable two point suspension scaffold system, there was a lack of an inspection of the "no power" emergency descend lever rendered inoperable due to the motor housing cover receiving damage after striking the building structure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4096

1926.502 D05

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $4,096 · Current $0 Reduced
29 CFR  1926.502(d)(5): Fall protection systems criteria and practices. Personal fall arrest systems. Snap-hooks shall be sized to be compatible with the member to which they are connected to prevent unintentional disengagement of the snap-hook by depression of the snap-hook keeper by the connected member, or shall be a locking type snap-hook designed and used to prevent disengagement of the snap-hook by the contact of the snap-hook keeper by the connected member. Effective January 1, 1998, only locking type snap-hooks shall be used.  a) On or about 04/08/2021, the snap-hooks and the wire rope being used by the employees working from an electrical powered adjustable two point suspension scaffold system were not compatible and that the snap-hook was not a locking type snap-hook.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4096

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345242119.