Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TENARIS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TENARIS in 1201 R ST., GENEVA, NE 68361 (NAICS 332312). OSHA activity number 345254213.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tenaris — free Get an email when a new federal OSHA severe-injury report for Tenaris is published. One employer, no account, unsubscribe in one click.
Establishment
TENARIS
Site address
1201 R ST.
City
GENEVA
State
NE
ZIP
68361
Mailing
1201 R ST., GENEVA, NE 68361
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
250
Ownership type
A

3 citations on file for this inspection.

1910.36 D01

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Jul 6, 2021
Penalty
Initial $3,805 · Current $3,000 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  The employer is failing to ensure that employees were protected from fire hazards. This was most recently documented at 1201 R Street, Geneva, Nebraska 68361 on April 15, 2021. A chain and hasp were being used to secure the exit route door from the inside that required special knowledge.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $3805

1910.303 B01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jul 6, 2021
Penalty
Initial $5,969 · Current $4,000 Reduced
29 CFR 1910.303(b)(1):  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  The employer is failing to ensure that employees were protected from electrical hazards. This violation was most recently documented at 1201 R Street, Geneva, Nebraska 68361 on April 15, 2021. Live electrical conductors were not contained within conduit for the heater at the Bundling Station.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $5969

1910.334 A02 I

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Jul 6, 2021
Penalty
Initial $5,969 · Current $4,000 Reduced
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  The employer is failing to ensure that employees were protected from electrical hazards. This violation was most recently documented at 1201 R Street, Geneva, Nebraska 68361 on April 15, 2021. Grounding pins were missing on the male plug on the following t limited to equipment.   a) Fan at the Bundling Station.   b) Nesco sand blaster.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $5969

View Tenaris's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345254213.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.