CLIFTON, NJ —
OSHA Inspection: ABUNDANT CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ABUNDANT CONSTRUCTION LLC in 14 BREEN CT, CLIFTON, NJ 07013 (NAICS 238130). OSHA activity number 345255368.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABUNDANT CONSTRUCTION LLC
- Site address
- 14 BREEN CT
- City
- CLIFTON
- State
- NJ
- ZIP
- 07013
- Mailing
- 9 ORCHARD ST, CLIFTON, NJ 07013
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- A
Citations
13 citations on file for this inspection.
1926.100 A
- Issued
- Jun 17, 2021
- Penalty
- Initial $3,511 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Exterior of Building - Ground Level - Front: Employees without any means of head protection were exposed to head injury while working on the ground level below carpenters installing plywood sheathing, on or about 4/8/21.
Recent events (3)
- — C (S) $3511
- — F (S) $1300
- — Z (S) $3511
1926.102 A01
- Issued
- Jun 17, 2021
- Abate by
- Jun 29, 2021
- Penalty
- Initial $1,755 · Current $800 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) Exterior of Building - Ground Level - Front: Employees without any means of eye protection were exposed to eye injury while engaged in excavation and masonry work on the ground level, on or about 4/8/21.
Recent events (3)
- — C (S) $1755
- — F (S) $800
- — Z (S) $1755
1926.300 B01
- Issued
- Jun 17, 2021
- Penalty
- Initial $2,926 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Exterior of Building - Foundation work - Front: Employees were exposed to amputation hazards while utilizing a hand held grinder without a guard, on or about 4/8/21.
Recent events (3)
- — C (S) $2926
- — F (S) $1200
- — Z (S) $2926
1926.403 B02
- Issued
- Jun 17, 2021
- Abate by
- Jun 29, 2021
- Penalty
- Initial $1,755 · Current $800 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Interior - 1st Floor: Employees and other workers were exposed to electric hazards while working around energized equipment including but not limited to loose 2"x4" plastic electric box with a double receptacle, on or about 4/16/21.
Recent events (3)
- — C (S) $1755
- — F (S) $800
- — Z (S) $1755
1926.405 G01 III B
- Issued
- Jun 17, 2021
- Abate by
- Jun 29, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(1)(iii)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a) Interior - 1st Floor: Energized electrical wire was run through the floor boards in order to connect to double outlet, on or about 4/16/21.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1926.404 B01 I
- Issued
- Jun 17, 2021
- Penalty
- Initial $1,755 · Current $800 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Interior - Basement: Employees and other workers engaged in construction activities were exposed to electric hazards while powering electric tools on outlets that were not protected by GFCI, on or about 4/8/21.
Recent events (3)
- — C (S) $1755
- — F (S) $800
- — Z (S) $1755
1926.416 A01
- Issued
- Jun 17, 2021
- Abate by
- Jun 29, 2021
- Penalty
- Initial $2,926 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) Exterior - Left Side - Electric Service Weatherhead: Employees and other workers were exposed to electric hazards while engaged in demolition activities approximately 2 feet from the secondary line, on or about 4/1/21. b) Exterior - Left Side - Electric Service Weatherhead: Employees and other workers were exposed to electric hazards while engaged in framing activities approximately 2 feet from secondary line, on or about 4/8/21. c) Exterior - Left Side - Electric Service Weatherhead: Employees and other workers were exposed to electric hazards while engaged in roofing activities approximately 2 feet from secondary line, on or about 4/16/21.
Recent events (3)
- — C (S) $2926
- — F (S) $1300
- — Z (S) $2926
1926.416 A03
- Issued
- Jun 17, 2021
- Abate by
- Jun 29, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): Employer did not post or maintain proper warning signs at locations where the performance of the work could bring a person, tool, or machine into physical or electrical contact with an energized electrical power circuit: a) Exterior - Left Side - Electric Service Weatherhead: No signage was posted to advise/warn employees and other workers engaged in demolition activities regarding the proximity of 2 feet or less from the energized secondary line, on or about 4/1/21. b) Exterior - Left Side - Electric Service Weatherhead: No signage was posted to advise/warn employees and other workers engaged in framing activities regarding the proximity of 2 feet or less from the energized secondary line, on or about 4/8/21. c) Exterior - Left Side - Electric Service Weatherhead: No signage was posted to advise/warn employees and other workers engaged in roofing activities regarding the proximity of 2 feet or less from the energized secondary line, on or about 4/16/21.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jun 17, 2021
- Abate by
- Jun 29, 2021
- Penalty
- Initial $4,096 · Current $1,700 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Exterior of Building - Roof: Employees without any means of fall protection were exposed to approximately 15 feet fall hazard while engaged in roofing activities, on or about 4/16/21. b) Interior of Building - 1st Floor: Employees were exposed to fall hazards of approximately 8 feet while engaged in several construction activities around the basement stairway shaft, on or about 4/16/21 and 4/22/21.
Recent events (3)
- — C (S) $4096
- — F (S) $1700
- — Z (S) $4096
1926.1051 A
- Issued
- Jun 17, 2021
- Penalty
- Initial $1,755 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Exterior of Building - Ground level: Employees and other workers were exposed to fall hazards while accessing the structure by climbing approximately 30" onto the 1st level, on or about 4/8/21.
Recent events (3)
- — C (S) $1755
- — F (S) $0
- — Z (S) $1755
1926.1052 C01 I
- Issued
- Jun 17, 2021
- Penalty
- Initial $1,755 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Exterior stairway to front porch - Employees and other workers were exposed to fall hazards of approximately 3 feet while accessing the front porch utilizing a masonry stairway without any handrail, on or about 4/8/21.
Recent events (3)
- — C (S) $1755
- — F (S) $0
- — Z (S) $1755
1926.1052 C01 I
- Issued
- Jun 17, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $23,405 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Interior Stairway to 2nd Floor - Employees and other workers were exposed to fall hazards of approximately 10 feet while accessing the 2nd floor utilizing a wooden stairway without any handrail, on or about 4/16/21 b) Interior Stairway to basement - Employees and other workers were exposed to fall hazards of approximately 8 feet while accessing the basement utilizing a wooden stairway without any handrail, on or about 4/16/21. c) Interior Stairway to 2nd Floor - Employees and other workers were exposed to fall hazards of approximately 10 feet while accessing the 2nd floor utilizing the same wooden stairway without any handrail, on or about 4/22/21. d) Interior Stairway to basement - Employees and other workers were exposed to fall hazards of approximately 8 feet while accessing the basement utilizing the same wooden stairway without any handrail, on or about 4/22/21.
Recent events (3)
- — C (W) $23405
- — F (S) $2100
- — Z (W) $23405
1926.1052 C01 II
- Issued
- Jun 17, 2021
- Abate by
- Jun 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Interior Stairway to 2nd Floor - Employees and other workers were exposed to fall hazards of approximately 10 feet while accessing the 2nd floor utilizing a wooden stairway without any handrail, on or about 4/16/21 b) Interior Stairway to 2nd Floor - Employees and other workers were exposed to fall hazards of approximately 10 feet while accessing the 2nd floor utilizing the same wooden stairway without any handrail, on or about 4/22/21.
Recent events (3)
- — C (W) $0
- — F (S) $0
- — Z (W) $0
More inspections in this industry (NAICS 238130)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345255368.