On , OSHA opened a complaint safety inspection of PURE GRANITE & STONE, LLC in 9978 SPRINGFIELD PIKE, CINCINNATI, OH 45215 (NAICS 327991). OSHA activity number 345257109.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pure Granite & Stone, LLC — free Get an email when a new federal OSHA severe-injury report for Pure Granite & Stone, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9978 SPRINGFIELD PIKE
City
CINCINNATI
State
OH
ZIP
45215
Mailing
9978 SPRINGFIELD PIKE, CINCINNATI, OH 45215
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
14
Ownership type
A

10 citations on file for this inspection.

1910.110 F02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 3, 2021
Abate by
Sep 30, 2021
Penalty
Initial $3,901 · Current $500 Reduced
29 CFR  1910.110(f)(2)(i): General. Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.  a) On or around April 29, 2021, three propane tanks that were used to fuel forklifts were stored outside near the back entrance at the bottom of the loading ramp and exposed to vehicular traffic.
Recent events (2)
  • — I (S) $500
  • — Z (S) $3901

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 3, 2021
Abate by
Oct 29, 2021
Penalty
Initial $5,461 · Current $1,000 Reduced
29 CFR  1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training, and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup, or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a) On or around April 19, 2021, the employer did not have an energy control program that included specific energy isolation procedures, training for authorized, affected, and other employees, and periodic inspections of the procedures on an annual basis for equipment such as but not limited to; the two Renegade Bridge saws.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $5461

1910.178 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 3, 2021
Abate by
Oct 29, 2021
Penalty
Initial $3,901 · Current $1,500 Reduced
29 CFR  1910.178(a)(4): General requirements. Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.    a) On or before April 19, 2021, the employer did not obtain the manufacturers prior written approval when the boom attachment used to move granite slabs was added to the Red Toyota forklift.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3901

1910.178 L03 I G

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 3, 2021
Abate by
Oct 12, 2021
Penalty
Initial $5,461 · Current $0 Reduced
29 CFR  1910.178(l)(3)(i)(G): Training program content. Truck-related topics: Fork and attachment adaptation, operation, and use limitations;  a) On or before April 19, 2021 the employees had not received adequate training in that they had not been trained on the use limitations of the boom lift attachment that is used to move stone slabs.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5461

1910.178 M05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2021
Penalty
Initial $3,121 · Current $2,000 Reduced
29 CFR  1910.178(m)(5)(i): Truck operations.  When a powered industrial truck is left unattended, load engaging means shall be fully lowered, controls shall be neutralized, power shall be shut off, and brakes set. Wheels shall be blocked if the truck is parked on an incline.  a) On or before April 19, 2021, the Red Toyota forklift was left unattended with the forks left in an elevated position with an extension boom attached.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3121

1910.212 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 3, 2021
Abate by
Dec 13, 2021
Penalty
Initial $5,461 · Current $2,500 Reduced
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and sparks. Examples of guarding methods are barrier guards, two-hand tripping devices, electronic safety devices, etc.  a) On or about April 19, 2021,  the two Renegade bridge saws did not utilize a guarding method that would prevent employees from getting caught in the moving 14" circular saw and struck by the bridge the saw was mounted to.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5461

1910.243 C03

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 3, 2021
Abate by
Oct 29, 2021
Penalty
Initial $5,461 · Current $2,500 Reduced
29 CFR  1910.243(c)(3): Portable abrasive wheels -Vertical portable grinders. Safety guards used on machines known as right angle head or vertical portable grinders shall have a maximum exposure angle of 180 deg., and the guard shall be so located so as to be between the operator and the wheel during use. Adjustment of guard shall be such that pieces of an accidentally broken wheel will be deflected away from the operator.  a) On or around April 19, 2021, the handheld electric powered Makita angle grinders used to cut stone did not have a guard on the grinding wheel.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5461

1910.303 B01 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Sep 3, 2021
Penalty
Initial $3,901 · Current $0 Reduced
29 CFR  1910.303(b)(1)(i): Examination.  Suitability for installation and use in conformity with the provisions of this subpart; Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose.  a) On or before April 19, 2021 there was a yellow extension cord plugged into an outlet on a support column in the stone storeroom, that was then fed up the column, along the wall, through a hole in the wall, wrapped around the conduit and ceiling supports, plugged into another extension cord that was then fed into the wet cutting room to power hand tools.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3901

1910.303 G02 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 3, 2021
Penalty
Initial $3,121 · Current $0 Reduced
29 CFR  1910.303(g)(2)(ii): 600 Volts, nominal, or less. Guarding of live parts.  In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards shall be so arranged and of such strength as to prevent such damage.   a) On or before April 19, 2021, the receptacle located on the left side of the overhead door leading to the outdoor ramp did not have a faceplate covering the outlets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3121

1910.305 J01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 3, 2021
Penalty
Initial $5,461 · Current $2,000 Reduced
29 CFR  1910.305(j)(1)(i):Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals.  a) On or before April 19, 2021, the junction box that could hold four receptacles located in the wet cutting area on the wall behind the table had exposed live wires on the left side.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5461

View Pure Granite & Stone, LLC's full OSHA safety record →