Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKY MOUNTAIN CABINET & COUNTERTOPS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROCKY MOUNTAIN CABINET & COUNTERTOPS, INC. in 500 WEST 7TH, SALIDA, CO 81201 (NAICS 337110). OSHA activity number 345260830.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rocky Mountain Cabinet & Countertops, INC. — free Get an email when a new federal OSHA severe-injury report for Rocky Mountain Cabinet & Countertops, INC. is published. One employer, no account, unsubscribe in one click.
Site address
500 WEST 7TH
City
SALIDA
State
CO
ZIP
81201
Mailing
500 WEST 7TH, SALIDA, CO 81201
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
13
Ownership type
A

5 citations on file for this inspection.

1910.213 H01

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 22, 2021
Penalty
Initial $3,121 · Current $2,000 Reduced
29 CFR  1910.213(h)(1): Radial saw(s) did not have an upper hood constructed in such a manner and of material that would have protected the operator from flying splinters, broken saw teeth, etc. and that deflected sawdust away from the operator:  (a) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not ensure that the Omga radial saw [model RM700, year 1994] in the cabinet box fabrication area was equipped with a front guard to protect against amputation and laceration hazards as well as flying chips and broken saw teeth. These conditions exposed employees to flying debris and amputation hazards.  (b) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not ensure that the Omga radial saw [model RM700, serial 01304513] was equipped with a front guard to protect against amputation and laceration hazards as well as flying chips and broken saw teeth. These conditions exposed employees to flying debris and amputation hazards.   Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3121

1910.1200 E01

Serious Gravity 1 1 instance 13 exposed
Issued
Jun 22, 2021
Abate by
Aug 9, 2021
Penalty
Initial $2,340 · Current $1,270 Reduced
29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   (a) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not develop or implement a written hazard communication program in accordance with this standard. This condition exposed employees to hazardous chemicals including but not limited to: -methyl-ethyl ketone -wood dust -methanol -ethanol -xylene -formaldehyde  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $1270
  • — Z (S) $2340

1910.1200 H01

Serious Gravity 1 1 instance 13 exposed
Issued
Jun 22, 2021
Abate by
Aug 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not provide effective information and training to employees in accordance with this standard. Informal training was given to employees however not in conjunction with a written hazard communication program. This condition exposed employees to hazardous chemicals including but not limited to: -methyl-ethyl ketone -wood dust -methanol -ethanol -xylene -formaldehyde  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Other-than-serious 1 instance 13 exposed
Issued
Jun 22, 2021
Abate by
Aug 9, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not establish an energy control program consisting of procedures, training, and annual inspections. This condition exposed employees to hazardous energy.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 2 instances 8 exposed
Issued
Jun 22, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   (a) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not ensure that the panel in the CNC area was clear of stored items and debris. This condition exposed employees to electric shock and fire hazards.  (b) Rocky Mountain Cabinet and Countertops, Inc. at 500 W 7th St. Salida, CO 81201: On or before 4/20/21 the employer did not ensure that the main panel was kept clear of items stored within 30 inches. Motor oil was stored within 30 inches of the panel. This condition exposed employees to electric shock and fire hazards.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Rocky Mountain Cabinet & Countertops, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345260830.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.