UTICA, NY —
OSHA Inspection: LEATHERSTOCKING PROFESSIONAL SERVICES, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LEATHERSTOCKING PROFESSIONAL SERVICES, LLC. in 253 GENESEE STREET, UTICA, NY 13501 (NAICS 236220). OSHA activity number 345262075.
Where did this inspection happen?
- Establishment
- LEATHERSTOCKING PROFESSIONAL SERVICES, LLC.
- Site address
- 253 GENESEE STREET
- City
- UTICA
- State
- NY
- ZIP
- 13501
- Mailing
- 2646 WELSHBUSH ROAD, FRANKFORT, NY 13340
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B02
- Issued
- Penalty
- Initial $1755.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Basement, ceiling area, on or about 4-21-21: Employees were using power that originated in a relocatable power tap (RPT), that was not being used in accordance with the manufacturer's recommendations or as listed and labeled. b) Basement, on concrete floor, on or about 4-21-21: Employees were using a duplex galvanized receptacle box that was lying on the floor and was not being used as "listed and labeled", in that it was not permanently mounted and not being used as designed and for its intended purpose.
Recent events (1)
- — Z (S) $1755
1926.404 B01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Basement, quad box below sub panel, off main panel, on or about 4-21-21: Employees were operating various hand-held power tools, cords, etc., powered through extension cords that were not protected by ground fault circuit interrupters (GFCI).
Recent events (1)
- — Z (S) $0
1926.416 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Basement, ceiling area, on or about 4-21-21: Employees were using an extension cord that was damaged.
Recent events (1)
- — Z (S) $0
1926.501 B04 II
- Issued
- Penalty
- Initial $1755.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers: a) First floor, main corridor, east end, on or about 4-21-21: Employees were walking/working in the immediate vicinity of three separate floor openings that were not protected, exposing the employees to a fall hazard of 9 feet 7 inches and/or 8 feet 7 inches to the basement below.
Recent events (1)
- — Z (S) $1755
1926.1052 C01 I
- Issued
- Penalty
- Initial $1755.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Stairway between second and third floor, on or about 4-21-21: Employees were using a stairway between the second and third floor that was not equipped with at least one handrail, exposing the employees to a fall hazard of up to 9 feet.
Recent events (1)
- — Z (S) $1755
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16 00:00:00
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16 00:00:00
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16 00:00:00
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16 00:00:00
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15 00:00:00
FC CONSTRUCTION LLC
More inspections in NY
MAYVILLE, NY—2026-07-16 00:00:00
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16 00:00:00
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16 00:00:00
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15 00:00:00
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15 00:00:00
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345262075.