APPLETON, WI —
OSHA Inspection: AARON GIL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AARON GIL in REMY LANE, APPLETON, WI 54913 (NAICS 238160). OSHA activity number 345275960.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AARON GIL
- Site address
- REMY LANE
- City
- APPLETON
- State
- WI
- ZIP
- 54913
- Mailing
- 802 W FRANKLIN ST, APPLETON, WI 54914
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Oct 28, 2021
- Abate by
- Nov 29, 2021
- Penalty
- Initial $279 · Current $279
General-duty citation text
29 CFR 1903.19(c)(1):Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section. On or about June 4, 2021, the employer did not certify that the hazardous conditions identified in Citation #1, Item # 2 of this inspection had been abated to provide eye protection to employees.
Recent events (1)
- — Z (O) $279
1926.501 B13
- Issued
- May 6, 2021
- Penalty
- Initial $2,984 · Current $2,984
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about April 28, 2021, employees of Aaron Gil were exposed to fall hazards of nine feet when they were engaged in roofing operations without the use of fall protection. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (1)
- — Z (S) $2984
1926.1053 B01
- Issued
- May 6, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about April 28, 2021, employees using a Keller K Pro KMT17 Multi-ladder to access a new residential constructions roof were exposed to fall hazards of 9 feet when the side rails of the ladder were not extended three feet above the landing surface.
Recent events (1)
- — Z (S) $0
1926.102 A01
- Issued
- May 6, 2021
- Abate by
- Jun 4, 2021
- Penalty
- Initial $2,487 · Current $2,487
General-duty citation text
29 CFR 1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about April 28, 2021, employees of Aaron Gil did not have appropriate eye protection when exposed to potential flying particles, such as nails or asphalt pieces, while using pneumatic nail guns to attach asphalt shingles to a new construction.
Recent events (1)
- — Z (S) $2487
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345275960.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.