Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUDION AUTOMATION LIMITED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AUDION AUTOMATION LIMITED in 775 BEREA INDUSTRIAL PARKWAY, BEREA, OH 44017 (NAICS 326112). OSHA activity number 345277214.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Audion Automation Limited — free Get an email when a new federal OSHA severe-injury report for Audion Automation Limited is published. One employer, no account, unsubscribe in one click.
Site address
775 BEREA INDUSTRIAL PARKWAY
City
BEREA
State
OH
ZIP
44017
Mailing
775 BEREA INDUSTRIAL PARKWAY, BEREA, OH 44017
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 27, 2021
Abate by
Nov 1, 2021
Penalty
Initial $7,510 · Current $3,755 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about September 17, 2021, the employer failed to ensure employees performing lockout/tagout on the Mada Promecam Press Break had machine specific lockout/tagout procedures. The employer had no machine specific procedures for machinery in the company.
Recent events (2)
  • — I (S) $3755
  • — Z (S) $7510

1910.147 C07 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 27, 2021
Abate by
Nov 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolatation:   On or about September 17, 2021, the employer failed to ensure employees performing lockout/tagout on the Mada Promecam Press Break were trained as authorized employees. Employees were trained as affected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Audion Automation Limited's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345277214.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.