Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LEELINCO PLASTICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LEELINCO PLASTICS, INC. in 1511 GENOA RED BLUFF, PASADENA, TX 77504 (NAICS 326199). OSHA activity number 345278857.

Watch Leelinco Plastics, INC. — free Get an email when a new federal OSHA severe-injury report for Leelinco Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1511 GENOA RED BLUFF
City
PASADENA
State
TX
ZIP
77504
Mailing
1511 GENOA RED BLUFF, PASADENA, TX 77504
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
35
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II B

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9557.00 · Current $0.00 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.   a)  On or about April 29, 2021, the specific procedure to de-energize Lathe #4 did not include the hydraulic energy.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9557

1910.147 D02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  a)  On or about April 29, 2021, at Warehouse 1, employees were exposed to struck-by-hazards when performing service and maintenance tasks on equipment such as, but not limited to, lathe #4 without de-energizing according to established procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $3277.00 Reduced
29 CFR  1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  a)  On or about April 29, 2021, at warehouse 2, where employees were exposed to caught-in hazards when operating a Von Dorn 1000 lathe, unit #20 without guarding the shaft.
Recent events (2)
  • — I (S) $3276.8
  • — Z (S) $4096

1910.304 F01 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $3277.00 Reduced
29 CFR  1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:   a)  On or about April 29, 2021 at Warehouse 1, where a breaker panel for the lathes #17 & #25 was obstructed by storage of miscellaneous parts.
Recent events (2)
  • — I (S) $3276.8
  • — Z (S) $4096

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $3277.00 Reduced
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) On or about April 29, 2021, at the repair shop,  where employees were exposed to electrical hazards when using an electrical panel with missing knockouts.
Recent events (2)
  • — I (S) $3276.8
  • — Z (S) $4096

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345278857.