BISMARCK, AR —
OSHA Inspection: J. A. FARMS FEED, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J. A. FARMS FEED, LLC in 2426 FINCH ROAD, BISMARCK, AR 71929 (NAICS 311119). OSHA activity number 345280713.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. A. FARMS FEED, LLC
- Site address
- 2426 FINCH ROAD
- City
- BISMARCK
- State
- AR
- ZIP
- 71929
- Mailing
- PO BOX 301, BISMARCK, AR 71929
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311119
- Employees
- 11
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.22 A01
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $4,681 · Current $2,600 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: On or about April 28, 2021: a. Employees working in the packaging room were exposed to trip and fall hazards from flexible cords for the conveyor belt, the Fuji stacking robot, and the fans lying on the floor. b. Employees working in the THMR mixer loading station were exposed to trip and fall hazards from flexible cords for the florescent bulbs and the World Weigh BWS scale lying on the floor.
Recent events (2)
- — I (S) $2600
- — Z (S) $4681
1910.28 B01 I A
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $5,461 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system: On the Colorado Mill Equipment (CME) pellet machine, employees were exposed to fall hazards of approximately 93-inches as a result of missing portions of guardrails.
Recent events (2)
- — I (S) $3000
- — Z (S) $5461
1910.212 A01
- Issued
- Oct 27, 2021
- Penalty
- Initial $3,121 · Current $1,900 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts: On or about April 28, 2021, on the northeast of the mill, the top of the auger from the hammer mill was not guarded, exposing employees to caught-in hazards from the rotating auger parts.
Recent events (2)
- — I (S) $1900
- — Z (S) $3121
1910.219 D01
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $5,461 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about April 28, 2021, the employer did not install guards over the following pulleys that exposed employees to caught-in hazards: a. The pulleys on the south, north, and top of the CME pellet machine. b. The pulleys on the west side of the red Van Dale mixer.
Recent events (2)
- — I (S) $2500
- — Z (S) $5461
1910.219 E01 I
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: On or about April 28, 2021, the employer did not install guards on the following horizontal belts that exposed employees to caught-in hazards: a. The belts on the south side of the CME pellet machine. b. The belts on the north side of the CME pellet machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)(a): On or about April 28, 2021, the employer did not install guards on the following vertical belts that exposed employees to caught-in hazards: a. The belts on top of the CME pellet machine. b. The vertical belt on the west side of the red Van Dale mixer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 II
- Issued
- Oct 27, 2021
- Abate by
- Nov 16, 2021
- Penalty
- Initial $5,461 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: On or about April 28, 2021: a. On the CME pellet machine, the flexible cord for the motor on the non-pelletized feed line was taped, exposing employees to electrical shock hazards. b. At the loading station for the THMR Kwikcutter 449 mixer, the flexible cord for the World Weigh BWS scale was frayed and taped, exposing employees to an electrical shock hazard of approximately 220 V.
Recent events (2)
- — I (S) $2800
- — Z (S) $5461
1910.305 G01 IV A
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $5,461 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about April 28, 2021, employees were exposed to electrical shock and burn hazards in that: a. On the CME pellet machine, flexible cords were used in place of fixed wiring to supply power to auger motors. b. On the 575ST Karsh mixer by the hammer mill, a flexible cord was used in place of fixed wiring to supply power to the Avery Weigh-Tronix XR 4500 scale. c. At the THMR Kwikcutter 449 mixer loading station, flexible cords were used in place of fixed wiring for the World Weigh BWS scale, and the florescent bulbs. d. In the packaging room, flexible cords were used in place of fixed wiring for the Fuji stacking robot, the conveyor belt, and the standing fans.
Recent events (2)
- — I (S) $0
- — Z (S) $5461
1910.305 B01 II
- Issued
- Oct 27, 2021
- Abate by
- Nov 16, 2021
- Penalty
- Initial $5,461 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about April 28, 2021 employees were exposed to electrical shock hazards in that: a. In the mill shop, the electrical cabinet was missing at least two knockouts and the cabinet doors were not effectively closed. b. In the mill shop, the disconnect and junction boxes for the Van Dale mixer were missing knockouts.
Recent events (2)
- — I (S) $2800
- — Z (S) $5461
1910.305 B02 I
- Issued
- Oct 27, 2021
- Abate by
- Nov 16, 2021
- Penalty
- Initial $5,461 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about April 28, 2021, employees were exposed to electric shock hazards in that: a. In the packaging room, a junction box did not have a cover. b. In the THMR Kwikcutter 449 mixer loading station, at least two outlet boxes did not have covers.
Recent events (2)
- — I (S) $0
- — Z (S) $5461
1910.303 E01 II
- Issued
- Oct 27, 2021
- Abate by
- Nov 23, 2021
- Penalty
- Initial $5,461 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Markings were not provided on electrical equipment for voltage, current, wattage and other ratings as necessary. On or about April 28, 2021: a. On the northeast wall in the mill shop, the electrical cabinets had no markings for voltage, current, and wattage. b. In the mill shop, the hammer mill did not have markings for voltage, current, and wattage.
Recent events (2)
- — I (O) $0
- — Z (S) $5461
More inspections at J. a. Farms Feed, LLC
View J. a. Farms Feed, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311119)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345280713.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.