Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KDJ SALES & SERVICE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KDJ SALES & SERVICE, INC. in 1947 EAST 2400TH ST., CAMP POINT, IL 62320 (NAICS 811310). OSHA activity number 345284301.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KDJ Sales & Service, INC. — free Get an email when a new federal OSHA severe-injury report for KDJ Sales & Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1947 EAST 2400TH ST.
City
CAMP POINT
State
IL
ZIP
62320
Mailing
708 SMITH STREET, MACKINAW, IL 61755
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.29 B02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Oct 15, 2021
Abate by
Nov 1, 2021
Penalty
Initial $6,827 · Current $0 Reduced
29 CFR  1910.29(b)(2):The employer did not ensure that midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members were installed between the walking-working surface and the top edge of the guardrail system when there was not a wall or parapet at least 21 inches (53 cm) high:  On or about April 27, 2021, an employee was exposed to fall hazards above fifteen feet when positioned on top of the Special Purpose Personnel Elevator (SPPE) and the employer did not ensure the guardrail system met the requirements  of the standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6827

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 15, 2021
Abate by
Nov 1, 2021
Penalty
Initial $5,461 · Current $3,823 Reduced
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about April 27, 2021, an employee suffered crushing injuries to abdominal area when the Special Purpose Personnel Elevator (SPPE) unexpectedly moved and the employee was caught between the guardrail and a structural.  The employer failed to implement energy control application steps as the SPPE was not isolated from the electrical energy source [per the 1910.147(d)(3) requirements].  As a result, the remaining applicable energy control elements, involving  LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from SPPE  hazards.