LONGMONT, CO —
OSHA Inspection: ARC COLORADO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ARC COLORADO, INC. in 7040 WELD COUNTY ROAD 20, LONGMONT, CO 80504 (NAICS 331110). OSHA activity number 345294623.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARC COLORADO, INC.
- Site address
- 7040 WELD COUNTY ROAD 20
- City
- LONGMONT
- State
- CO
- ZIP
- 80504
- Mailing
- 7040 WELD COUNTY ROAD 20, LONGMONT, CO 80504
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 280
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 I
- Issued
- Sep 7, 2021
- Abate by
- Sep 24, 2021
- Penalty
- Initial $12,288 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) ARC Colorado, Inc. at 7040 Weld County Road 20, Longmont, CO 80504: On and before May 5, 2021, machine specific, step-by-step procedures were not developed, documented and utilized for the control of hazardous energy when employees conducted maintenance activities on machinery including but not limited to the: - dust collector - Robodrill - Encon Evaporator This condition exposed employees to laceration and amputation hazards. An employee experienced an partial amputation while working on the dust collector which was not properly isolated from energy sources during servicing and maintenance. Abatement Note: Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 1) A specific statement of the intended use of the procedures; 2) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; 3) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and 4) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
- — I (S) $0
- — Z (S) $12288
More inspections in this industry (NAICS 331110)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345294623.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.