WASHINGTON, DC —
OSHA Inspection: MANUEL'S ROOFING & GUTTERS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANUEL'S ROOFING & GUTTERS LLC in 4522 49TH STREET NW, WASHINGTON, DC 20016 (NAICS 238160). OSHA activity number 345296743.
Where did this inspection happen?
- Establishment
- MANUEL'S ROOFING & GUTTERS LLC
- Site address
- 4522 49TH STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 3 BUSH HILL CRT, GAITHERSBURG, MD 20882
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $4096.00
General-duty citation text
29 CFR 1926.102(a)(1):Employees did not use eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about May 7, 2021 - Employees were observed working on the roof with a pneumatic nail gun without wearing eye protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet
Recent events (1)
- — Z (S) $4096
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $4096.00
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about May 7, 2021 - Employees wearing climbing belts were exposed to a fall hazard of up to 30 feet while installing shingles. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4096
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about May 7, 2021 - The employer failed to certify fall protection training where employees are exposed to fall hazards in excess of six feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet.
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2926.00 · Current $2926.00
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed a) On or about May 7, 2021 - Employees were using an extension ladder at the front of the residence to access the roof, was only extended 16 inches above the landing. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $2926
More inspections in this industry (NAICS 238160)
PORTLAND, OR—2026-07-17 00:00:00
317744797 - JBC ROOFING LLC
MERIDIAN, ID—2026-07-17 00:00:00
COBRA'S ROOFING LLC
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
BRADLEY, IL—2026-07-16 00:00:00
JUAN CRUZ DBA ROOFBOYS LLC
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
More inspections in DC
WASHINGTON, DC—2026-06-30 00:00:00
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16 00:00:00
MACY'S
WASHINGTON, DC—2026-06-02 00:00:00
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02 00:00:00
DDC CPL LLC
WASHINGTON, DC—2026-06-02 00:00:00
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345296743.