Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LION KING HI GENERAL CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LION KING HI GENERAL CONSTRUCTION in 496 BURTON AVE, HASBROUCK HEIGHTS, NJ 07604 (NAICS 236116). OSHA activity number 345298012.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lion King HI General Construction — free Get an email when a new federal OSHA severe-injury report for Lion King HI General Construction is published. One employer, no account, unsubscribe in one click.
Site address
496 BURTON AVE
City
HASBROUCK HEIGHTS
State
NJ
ZIP
07604
Mailing
496 BURTON AVE, HASBROUCK HEIGHTS, NJ 07604
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
19
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
Sep 10, 2021
Penalty
Initial $2,340 · Current $0 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles.   a) Ladder - Front of Building: Employee without any eye and or face protection was exposed to eye injury while installing wire mesh from a ladder, on or about 3/25/21.  b) Roof - Back of Building: Employee without any eye and or face protection was exposed to eye injury while installing wire mesh from the roof, on or about 3/25/21.
Recent events (3)
  • — J (S) $0
  • — C (S) $2340
  • — Z (S) $2340

1926.405 B02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 10, 2021
Penalty
Initial $4,681 · Current $0 Reduced
29 CFR  1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:    a) Ladder - Front of Building: Employee was exposed to electric shock while installing wire mesh from an aluminum ladder next to an energized uncovered junction box, on or about 3/25/21.
Recent events (3)
  • — J (S) $0
  • — C (S) $4681
  • — Z (S) $4681

1926.416 A01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Sep 10, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a) Exterior - Front - Service Line: Employees were exposed to electric hazards while installing wire mesh on the wall around the service line, on or about 3/25/21.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B13

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2021
Penalty
Initial $5,461 · Current $0 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) Roof - Back of Building: Employee  without any means of fall protection was exposed to fall hazards of approximately 12 feet  while engaged in masonry activities installing wire mesh from the roof, on or about 3/25/21.
Recent events (3)
  • — J (S) $0
  • — C (S) $5461
  • — Z (S) $5461

1926.1053 B01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2021
Penalty
Initial $5,461 · Current $0 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) Roof - Back of Building: Employee was exposed to 12 foot fall hazard while utilizing an extension ladder that extended only approximately 6 " above the accessed deck, on or about 3/25/21.
Recent events (3)
  • — J (S) $0
  • — C (S) $5461
  • — Z (S) $5461

View Lion King HI General Construction's full OSHA safety record →