Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WALKER MECHANICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WALKER MECHANICAL, INC. in 175 WILLIAM F MCCLELLAN HWY, EAST BOSTON, MA 02228 (NAICS 221114). OSHA activity number 345298301.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Walker Mechanical, INC. — free Get an email when a new federal OSHA severe-injury report for Walker Mechanical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
175 WILLIAM F MCCLELLAN HWY
City
EAST BOSTON
State
MA
ZIP
02228
Mailing
32 WINN STREET, BURLINGTON, MA 01803
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
2
Ownership type
A

2 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 4, 2021
Penalty
Initial $4,096 · Current $1,000 Reduced
29 CFR  1910.28(b)(1)(i):(1) Unprotected sides and edges.  (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following:    Location: On the Roof  Employees were exposed to falls from heights of approximately 16 feet to the ground while conducting HVAC maintenance on an unprotected roof where fall protection was not utilized.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4096

1910.30 A03 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 4, 2021
Penalty
Initial $2,926 · Current $1,000 Reduced
29 CFR  1910.30(a)(3)(iv): The employer did not train each employee in the correct use of personal fall protection systems and equipment specified in paragraph (a)(1) of this section, including, but not limited to, proper hook-up, anchoring, and tie-off techniques, and methods of equipment inspection and storage, as specified by the manufacturer.   Location: On the Roof  Employees were exposed to falls from heights of approximately 16 feet to the ground while conducting HVAC maintenance on an unprotected roof where the employer did not train each employee on anchoring, tie-off techniques, and/or methods of inspecting and storing fall protection equipment per manufacturer's instructions.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2926

View Walker Mechanical, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345298301.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.