EAST HARTFORD, CT —
OSHA Inspection: RIVERA'S PROPERTIES LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIVERA'S PROPERTIES LLC in 212 BURNSIDE AVENUE, EAST HARTFORD, CT 06108 (NAICS 236118). OSHA activity number 345302384.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIVERA'S PROPERTIES LLC
- Site address
- 212 BURNSIDE AVENUE
- City
- EAST HARTFORD
- State
- CT
- ZIP
- 06108
- Mailing
- 127 PRESTON STREET, 1ST FLOOR, HARTFORD, CT 06114
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Sep 30, 2021
- Penalty
- Initial $2,926 · Current $2,048 Reduced
General-duty citation text
29 CFR 1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. On or about May 11, 2021 at the Faro Restaurant Re-roofing Project, employees were installing a roofing system to the roof deck which was less than 50 feet in width and exposed to falls of about 14 feet and no fall protection system such as the safety monitoring system was in use.
Recent events (2)
- — I (S) $2048.2
- — Z (S) $2926
1926.1053 B01
- Issued
- Sep 30, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about May 11, 2021 at the Faro Restaurant Re-roofing Project, the employees were using an extension ladder to access the roof deck and the ladder did not extend 3 feet past the roof deck.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236118)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345302384.