NORMAN, OK —
OSHA Inspection: KEVIN MIRANDA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEVIN MIRANDA in 1822 CRESTMONT AVE, NORMAN, OK 73069 (NAICS 238160). OSHA activity number 345304091.
Where did this inspection happen?
- Establishment
- KEVIN MIRANDA
- Site address
- 1822 CRESTMONT AVE
- City
- NORMAN
- State
- OK
- ZIP
- 73069
- Mailing
- 7111 NW 45TH STREET, BETHANY, OK 73008
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2341.00 · Current $2341.00
General-duty citation text
29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502 On or about May 12, 2021, The employer did not ensure employees, performing roof work activities were in use of fall protection. This exposed the employees to a fall hazard greater than Ten(10 ) feet to the ground below.
Recent events (1)
- — Z (S) $2341
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2341.00 · Current $2341.00
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. On or about May 12, 2021, the employer did not ensure employees, performing roof work activities, properly placed the ladder at the correct height above the upper landing surface. This exposed the employees to an improperly extended ladder for proper support when grabbing the ladder to climb or descend from the upper landing surface.
Recent events (1)
- — Z (S) $2341
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345304091.