Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUXCO

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LUXCO in 5050 KEMPER AVENUE, SAINT LOUIS, MO 63139 (NAICS 312140). OSHA activity number 345306443.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luxco — free Get an email when a new federal OSHA severe-injury report for Luxco is published. One employer, no account, unsubscribe in one click.
Establishment
LUXCO
Site address
5050 KEMPER AVENUE
City
SAINT LOUIS
State
MO
ZIP
63139
Mailing
5050 KEMPER AVENUE, SAINT LOUIS, MO 63139
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312140
Employees
40
Ownership type
A

11 citations on file for this inspection.

1910.22 A02

Other-than-serious Gravity 1 1 instance 15 exposed
Issued
Sep 17, 2021
Penalty
Initial $3,133 · Current $0 Reduced
29 CFR  1910.22(a)(2): The employer did not ensure that the  floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition:  5050 Kemper Dr. St. Louis, MO 63139, Production area: Employer is exposing employees to hazardous condition.  The employees are permitted to walk where there is water on workplace floor. On 5/13/2021 employees were observed walking on wet floors in non-production area.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3133

1910.28 B07

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $2,000 Reduced
29 CFR 1910.28(b)(7): The employer did not ensure that each employee on a walking-working surface near an opening 4 feet (1.2 m) or more above a lower level is protected from falling:     5050 Kemper Ave, St. Louis MO 63139: Employer is exposing employees to hazardous conditions where the employees are permitted to use a stairway which have unguarded openings.  On and about 5/13/2021 employees used ship stairs above which there was an opening greater than 48 inches to the floor.  The employees were exposed to fall hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $5223

1910.37 B02

Other-than-serious Gravity 1 1 instance 10 exposed
Issued
Sep 17, 2021
Penalty
Initial $3,133 · Current $2,000 Reduced
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to hazardous conditions where the employees use a door for exit purposes.  On 5/13/2021 employees were observed using a door for exit purposes.  The door did not have a sign identifying it as an exit door.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $3133

1910.37 B05

Other-than-serious Gravity 1 1 instance 25 exposed
Issued
Sep 17, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  5050 Kemper Ave, St. Louis MO 63139:  Employer is exposing employees to hazardous conditions where the employees work  by a door which can be mistaken for an exit. On 5/13/2021 employees were exposed to a hazardous condition where a door which could be mistaken for an exit was not labeled with its purpose or "NOT AN EXIT" sign.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 15 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $4,000 Reduced
29 CFR  1910.178(q)(7): Industrial trucks were not examined before being placed in service:   5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to hazardous conditions where the employees are permitted to operate forklifts without performing  required daily safety examinations to identify any defects which pose safety hazards. On 5/13/2021 an employee operated a forklift which did not undergo required safety examination to identify defects such as, but not limited to, non-functioning hazard warning light thereby exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5223

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $4,000 Reduced
29 CFR  1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:   5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to hazardous conditions where the employees are permitted to operate unguarded equipment. On and about 5/13/2021 employees used an unguarded drill press, unguarded metal band saw, and a lathe which did not have a guard on the drum exposing the employees to amputation hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5223

1910.212 A05

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $0 Reduced
29 CFR  1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to amputation hazards where the employees are permitted to use floor fans which are not adequately guarded.   On 5/13/2021 employees were exposed to amputation hazards where the guard openings on floor fans were larger than 1/2 inch.  The blade peripheries of the fans were less than 4 feet above the workplace floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5223

1910.215 B09

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 17, 2021
Penalty
Initial $3,133 · Current $0 Reduced
29 CFR  1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to hazardous conditions where the employees are permitted to operate unguarded equipment. On and about 5/13/2021 employees in the Maintenance Department used a bench grinder which had a tongue guard missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3133

1910.303 B07 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $4,000 Reduced
29 CFR  1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to electrical hazards.  The employees are permitted to work where there are damaged electrical components. On and about 5/13/2021 employees were exposed to electrical hazards where the upper receptacle of a duplex outlet in use in the C-Line was damaged.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5223

1910.303 G02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $0 Reduced
29 CFR  1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:   5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to electrical hazards where the employees are permitted to operate electrical equipment which has exposed live parts.  On and about 5/13/2021 employees operated a drill press connected to exposed live parts of a duplex outlet exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5223

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2021
Penalty
Initial $5,223 · Current $0 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  5050 Kemper Ave, St. Louis, MO 63139: Employer is exposing employees to hazardous conditions where the employees are permitted to operate electrical equipment with defects. On and about 5/13/2021 employees operated electrical outlet box and an electrical switch box which had knockouts missing exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5223

View Luxco's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345306443.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.