PONTOTOC, MS —
OSHA Inspection: C&C MACHINE AND FABRICATION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C&C MACHINE AND FABRICATION LLC in 420 E OXFORD ST, PONTOTOC, MS 38863 (NAICS 332710). OSHA activity number 345311500.
Where did this inspection happen?
- Establishment
- C&C MACHINE AND FABRICATION LLC
- Site address
- 420 E OXFORD ST
- City
- PONTOTOC
- State
- MS
- ZIP
- 38863
- Mailing
- 420 OXFORD ST, PONTOTOC, MS 38863
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 17
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.110 E02 IV
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $2731.00 Reduced
General-duty citation text
29 CFR 1910.110(e)(2)(iv):LP-Gas fueled industrial trucks did not comply with the Standard for Type Designations, Areas of Use, Maintenance and Operation of Powered Industrial Trucks, NFPA 505-1969, which is incorporated by reference as specified in Sec. 1910.6: (a) Propane cylinders on powered industrial vehicles; The employer did not ensure that propane cylinders used to fuel the forklift were within their hydrostatic test date, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
1910.178 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(f)(2):29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel shall be in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6: (a) Powered Industrial Vehicles (PIV): The employer was utilizing propane cylinders which were past their hydrostatic test date, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $2731.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a)Throughout the facility; The employer did not develop an Energy Control Program for employees required to perform maintenance, repairs, cleaning, and tool changes for equipment such as but not limited to band saws and CNC Lathes at the facility, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $2731.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i):The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Throughout the facility; The employer did not ensure employees required to operate the powered industrial vehicles (PIV) at the facility were trained according to requirements listed in CFR 1910.178(l)(2), exposing employees to struck by hazards.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $2731.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Throughout the facility; On or about May 12, 2021 the employer did not ensure guards were in place on the CNC Lathes and rotating sanders, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
1910.212 A03 IV F
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(f):The point of operation of power saws whose operation exposed an employee to injury were not guarded: Bandsaw: The employer did not ensure that an employee operating the band saw cutting pipe had adjusted the blade guard to prevent exposure to the unused portion of the blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source