Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VITRO ARCHITECTURAL GLASS INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VITRO ARCHITECTURAL GLASS INCORPORATED in 400 PARK DRIVE, CARLISLE, PA 17015 (NAICS 327211). OSHA activity number 345322952.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vitro Architectural Glass Incorporated — free Get an email when a new federal OSHA severe-injury report for Vitro Architectural Glass Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
400 PARK DRIVE
City
CARLISLE
State
PA
ZIP
17015
Mailing
400 PARK DRIVE, CARLISLE, PA 17015
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327211
Employees
390
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 35 exposed
Issued
Oct 13, 2021
Abate by
Nov 8, 2021
Penalty
Initial $13,653 · Current $13,653
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Wareroom - The packer conveyor lines had energy sources to include electric, compressed air, and potential energy.  The employer had a written machine-specific Wareroom Packer Cullet Conveyor 1 and Cullet Gate Conveyor lockout/tagout procedure; however, the procedure did not include compressed air as an energy source and so did not include steps for how to de-energize and lockout/tagout compressed air, exposing employees to getting struck-by and caught-in moving machine parts, on or about May 10, 2021.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $13653
  • — Z (S) $13653

1910.147 D04 I

Other-than-serious Gravity 10 1 instance 28 exposed
Issued
Oct 13, 2021
Abate by
Nov 8, 2021
Penalty
Initial $13,653 · Current $0 Reduced
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Wareroom - Employees did not lockout/tagout when going underneath packer conveyor lines, including the 1D Packer, to troubleshoot a stuck Cullet Gate, exposing employees to getting caught-in and struck-by moving machinery, such as the counterweight on the gearbox for the Cullet Gate's motor, on or about May 10, 2021.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $13653

1910.212 A01

Serious Gravity 10 1 instance 28 exposed
Issued
Oct 13, 2021
Abate by
Nov 8, 2021
Penalty
Initial $13,653 · Current $13,653
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Wareroom - Air valves for packer conveyor lines, including the Cullet Gate on 1D Packer, were underneath the conveyor lines, so employees had to go underneath the machinery to lockout/tagout the air valves, exposing employees to getting struck-by and caught-in moving machine parts when accessing an energy isolating device, on or about May 10, 2021.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $13653
  • — Z (S) $13653

1910.219 C04 I

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Oct 13, 2021
Abate by
Nov 8, 2021
Penalty
Initial $7,802 · Current $1,951 Reduced
29 CFR  1910.219(c)(4)(i): Unguarded projecting shaft ends did not present a smooth edge and end and projected more than one half the diameter of the shaft:  (a) Wareroom - A motor, 14.5 inches above the work platform, for the inspection conveyor on the 1D Packer, near the operator control station, had an unguarded shaft end that projected 2 inches,  exposing employees to a caught-in rotating parts hazard, on or about May 21, 2021.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $1950.6
  • — Z (S) $7802

View Vitro Architectural Glass Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345322952.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.