VERONA, WI —
OSHA Inspection: S & E ENTERPRISES OF VERONA, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of S & E ENTERPRISES OF VERONA, INC. in 300 EAST VERONA AVE, VERONA, WI 53593 (NAICS 237110). OSHA activity number 345328629.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S & E ENTERPRISES OF VERONA, INC.
- Site address
- 300 EAST VERONA AVE
- City
- VERONA
- State
- WI
- ZIP
- 53593
- Mailing
- P.O BOX 930249, VERONA, WI 53593
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Sep 15, 2021
- Abate by
- Sep 29, 2021
- Penalty
- Initial $4,096 · Current $1,865 Reduced
General-duty citation text
29 CFR 1926.100(a):Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: On or about May 26, 2021, employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact or from falling or flying objects.
Recent events (2)
- — I (S) $1865
- — Z (S) $4096
1926.651 C02
- Issued
- Sep 15, 2021
- Abate by
- Sep 29, 2021
- Penalty
- Initial $2,926 · Current $1,865 Reduced
General-duty citation text
29 CFR 1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about May 26, 2021, a stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet or more in depth.
Recent events (2)
- — I (S) $1865
- — Z (S) $2926
1926.651 J02
- Issued
- Sep 15, 2021
- Abate by
- Sep 29, 2021
- Penalty
- Initial $4,096 · Current $1,865 Reduced
General-duty citation text
29 CFR 1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. On or about May 26, 2021, protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet from the edge of the excavation.
Recent events (2)
- — I (S) $1865
- — Z (S) $4096
1926.651 K01
- Issued
- Sep 15, 2021
- Abate by
- Dec 1, 2021
- Penalty
- Initial $4,096 · Current $2,194 Reduced
General-duty citation text
29 CFR 1926.651(k)(1):Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. On or about May 26, 2021, the excavation and adjacent areas were not inspected by a competent person.
Recent events (2)
- — I (S) $2194
- — Z (S) $4096
1926.652 A01
- Issued
- Sep 15, 2021
- Abate by
- Sep 29, 2021
- Penalty
- Initial $4,096 · Current $2,611 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about May 26, 2021, employees working in an excavation were not provided from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).
Recent events (2)
- — I (S) $2611
- — Z (S) $4096