Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARQUEZ BRICK WORK INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MARQUEZ BRICK WORK INC in 3230 11TH STREET NW, WASHINGTON, DC 20015 (NAICS 238140). OSHA activity number 345334619.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marquez Brick Work INC — free Get an email when a new federal OSHA severe-injury report for Marquez Brick Work INC is published. One employer, no account, unsubscribe in one click.
Site address
3230 11TH STREET NW
City
WASHINGTON
State
DC
ZIP
20015
Mailing
8802 JENNA CT, LANHAM, MD 20706
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 B05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 30, 2021
Abate by
Oct 6, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.451(b)(5)(i):The end of a platform 10 feet or less in length, extended over its support more than 12 inches:  a) On or about May 27, 2021 - On the Eastside of the project planks on the outrigger of the scaffold system extended approximately 24-36 inches beyond the support frame exposing the employees to a fall hazard of approximately 24 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4096

1926.451 G04 III

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 30, 2021
Abate by
Oct 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(iii):When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they were not installed between the top edge of the guardrail system and the scaffold platform.  a) On or about May 27, 2021 - Where  employees were performing masonry work on the eastside of the site a scaffold had been erected and the employer did not install mid-rails along the working level.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2021
Abate by
Oct 6, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:   a) On or about May 27, 2021 - A toeboard was not installed where employees were working on the fourth level of a scaffold performing masonry work  and where there was  tools or materials  present.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2021
Abate by
Oct 7, 2021
Penalty
Initial $2,487 · Current $2,487
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about May 27, 2021 -  An employee standing at the edge of a  roof without fall protection was exposed to a fall hazard of approximately 10 feet while assisting to provide masonry supplies to employees on the scaffold.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2487

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2021
Abate by
Oct 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about May 27, 2021 - Where employees were performing masonry work and exposed to fall hazards greater than 6-feet the employer did not provide certification of fall protection training.  In accordance with 29 CFR 1903.19(d), abatement ce1tification is required for this violation (using the Certification of Corrective Action Worksheet)
Recent events (1)
  • — Z (O) $0

View Marquez Brick Work INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345334619.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.