2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PARO CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PARO CONSTRUCTION in 31 BROAD STREET, PULASKI, NY 13142 (NAICS 238160). OSHA activity number 345340715.

Watch Paro Construction — free Get an email when a new federal OSHA severe-injury report for Paro Construction is published. One employer, no account, unsubscribe in one click.
Establishment
PARO CONSTRUCTION
Site address
31 BROAD STREET
City
PULASKI
State
NY
ZIP
13142
Mailing
PO BOX 474, PULASKI, NY 13142
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $4096.00 · Current $3072.00 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a)  31 Broad Street, Pulaski, NY  13142, on or about 6/2/21:  Workers transited across an 8:12 roof surface, with a ground to eave height of 13 feet, approximately 20 feet from the ladder access point to another roof surface (where work was being conducted) without fall protection of any kind.    b)  31 Broad Street, Pulaski, NY  13142, on or about 6/2/21:  Workers were stripping a 6:12 roof surface with a ground to eave height of 22 feet, without fall protection of any kind.
Recent events (2)
  • — I (S) $3072
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $4096.00 · Current $3072.00 Reduced
29 CFR  1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:   a)  31 Broad Street, Pulaski, NY  13142, on or about 6/2/21:  Workers accessed a roof surface, 21 feet from ground, from an extension ladder that extended only one foot from the point of access.