CEDAR HILL, TX —
OSHA Inspection: JOSE MEJIA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOSE MEJIA in 2710 MELISSA CT, CEDAR HILL, TX 75104 (NAICS 238160). OSHA activity number 345344014.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOSE MEJIA
- Site address
- 2710 MELISSA CT
- City
- CEDAR HILL
- State
- TX
- ZIP
- 75104
- Mailing
- 1221 LAKE SIDE DR, GARLAND, TX 75040
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 16, 2021
- Abate by
- Aug 11, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On June 2, 2021. Employee was repairing roof on a residential house roof approximately 20 feet in height without the use of fall protection, exposing employee to a fall hazard.
Recent events (1)
- — Z (S) $4096
1926.1053 B01
- Issued
- Jul 16, 2021
- Abate by
- Aug 11, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about June 2, 2021 Employee was exposed to a fall of approximately 12 feet to the lower ground level by not having the ladder extended 3 feet above the landing.
Recent events (1)
- — Z (S) $4096
More inspections at Jose Mejia
View Jose Mejia's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345344014.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.