Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREAT LAKES TV SEAL INC.

Federal Agency inspection · Health discipline

On , OSHA opened a federal Agency health inspection of GREAT LAKES TV SEAL INC. in N10114 GULIG ROAD, MALONE, WI 53049 (NAICS 541990). OSHA activity number 345350532.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Great Lakes TV Seal INC. — free Get an email when a new federal OSHA severe-injury report for Great Lakes TV Seal INC. is published. One employer, no account, unsubscribe in one click.
Site address
N10114 GULIG ROAD
City
MALONE
State
WI
ZIP
53049
Mailing
3600 KEWAUNEE ROAD, GREEN BAY, WI 54311
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541990
Employees
3
Ownership type
A

9 citations on file for this inspection.

1910.134 G01 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2021
Abate by
Dec 28, 2021
Penalty
Initial $3,901 · Current $3,901
29 CFR  1910.134(g)(1)(i)(A): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have: Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function:  On or about June 3, 2021, through October 20, 2021, employees were exposed to atmospheric hazards while spraying Macropoxy 5500 2-Part Epoxy Primer in five Town of Calumet Sanitation District #1 County Trunk W Area sewer manholes and sewer manholes at other locations due to the fact the employer permitted the use of tight fitting 3M 6800 full face cartridge respirators with facial hair located in the area of the respirator sealing surface.
Recent events (2)
  • — I (S) $3901
  • — Z (S) $3901

1910.146 D03 VI

Serious Gravity 5 2 instances 14 exposed
Issued
Nov 29, 2021
Abate by
Jan 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.146(d)(3)(vi): Develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, the following: (vi) Verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry.  On or about June 7, 2021, the Employer failed to develop and implement consistent practices and procedures related to when additional air monitoring shall be performed and recorded on the Confined Space Entry Permit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1048 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 29, 2021
Abate by
Dec 28, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.1048(d)(2):Initial monitoring. The employer shall identify all employees who may be exposed at or above the action level or at or above the STEL and accurately determine the exposure of each employee so identified.  On or about June 3, 2021, the employer failed to evaluate the employees' exposure to formaldehyde during sprayer setup and while spraying Macropoxy 5500 2-part Epoxy Primer inside sewer manholes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 D03 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 29, 2021
Abate by
Jan 28, 2022
Penalty
Initial $5,461 · Current $5,461

Hazardous substances 1480

29 CFR  1910.146(d)(3)(iv): Develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, the following: (iv) Purging, inerting, flushing, or ventilating the permit space as necessary to eliminate or control atmospheric hazards:  On or about June 7, 2021, Employees were exposed to atmospheric hazards while entering sewer manholes due to the fact the Employer failed to ensure manholes were adequately ventilated and failed to develop and implement practices and procedures related to when powered ventilation shall be used during entries into sewer manholes and other permit required confined spaces.
Recent events (2)
  • — I (S) $5461
  • — Z (S) $5461

1910.146 D05 I

Serious Gravity 10 3 instances 1 exposed
Issued
Nov 29, 2021
Abate by
Jan 28, 2022
Penalty
Initial $0 · Current $0

Hazardous substances 1480

29 CFR  1910.146(d)(5)(i):Test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorized to begin, except that, if isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), pre-entry testing shall be performed to the extent feasible before entry is authorized and, if entry is authorized, entry conditions shall be continuously monitored in the areas where authorized entrants are working;  On or about June 7, 2021, employees were exposed to atmospheric hazards while entering sewer manholes due to the fact the Employer failed to ensure pre-entry testing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1000 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 29, 2021
Abate by
Dec 28, 2021
Penalty
Initial $0 · Current $0

Hazardous substances 1480

29 CFR  1910.1000(b)(2):Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under "acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift" Table Z-2 Hydrogen Sulfide  "Acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift" is 50 ppm.  "Acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift Maximum duration" is 10 mins. once, only if no other meas. exp. occurs:  On or about June 7, 2021, an employee was exposed to a hydrogen sulfide concentration over 100 parts per million for at least 10 minutes after entering the Town of Calumet Sanitation District #1 Manhole #38.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 E01

Serious Gravity 10 3 instances 1 exposed
Issued
Nov 29, 2021
Abate by
Dec 28, 2021
Penalty
Initial $5,461 · Current $5,461

Hazardous substances 1480

29 CFR  1910.146(e)(1):Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit:  On or about June 7, 2021, Employees were exposed to hazards associated with confined space entry due to the fact the Employer failed to ensure confined space entry permits were completed prior to entering sewer manholes.
Recent events (2)
  • — I (S) $5461
  • — Z (S) $5461

1910.146 K02 IV

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Nov 29, 2021
Abate by
Dec 28, 2021
Penalty
Initial $5,461 · Current $0 Reduced
29 CFR  1910.146(k)(2)(iv):Ensure that affected employees practice making permit space rescues at least once every 12 months, by means of simulated rescue operations in which they remove dummies, manikins, or actual persons from the actual permit spaces or from representative permit spaces. Representative permit spaces shall, with respect to opening size, configuration, and accessibility, simulate the types of permit spaces from which rescue is to be performed.  On or about June 7, 2021, employees were exposed to hazards associated with confined space entry and the employer failed to conduct simulated rescue operations with affected employees at least once every 12 months.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5461

1910.146 K03

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 29, 2021
Abate by
Dec 28, 2021
Penalty
Initial $5,461 · Current $5,461

Hazardous substances 1480

29 CFR  1910.146(k)(3):To facilitate non-entry rescue, retrieval systems or methods shall be used whenever an authorized entrant enters a permit space, unless the retrieval equipment would increase the overall risk of entry or would not contribute to the rescue of the entrant. Retrieval systems shall meet the following requirements.  On or about June 7, 2021, employees were exposed to hazards associated with confined space entry and the employer failed to ensure an adequate non-entry retrieval system was utilized.
Recent events (2)
  • — I (S) $5461
  • — Z (S) $5461

View Great Lakes TV Seal INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345350532.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.