OSHA Inspection: MILLER CONTAINER CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MILLER CONTAINER CORPORATION in 3402 78TH AVE WEST, ROCK ISLAND, IL 61201 (NAICS 322211). OSHA activity number 345356950.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miller Container Corporation — free Get an email when a new federal OSHA severe-injury report for Miller Container Corporation is published. One employer, no account, unsubscribe in one click.
Site address
3402 78TH AVE WEST
City
ROCK ISLAND
State
IL
ZIP
61201
Mailing
P.O. BOX 1130, MILAN, IL 61264
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
200
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 30, 2021
Penalty
Initial $9,753 · Current $5,851 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about May 28, 2021, employees were exposed to amputation hazards when operating and maintaining the Bobst SPO-2000, Automatic Platen Die Cutter because of an unguarded chain and sprocket on the Automatic Pile Transfer conveyor.
Recent events (2)
  • — I (S) $5851
  • — Z (S) $9753

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2021
Abate by
Nov 1, 2021
Penalty
Initial $7,802 · Current $4,682 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  On or about June 10, 2021 and at times prior, the employer did not ensure that before any servicing or maintenance on the Bobst SPO-2000 was conducted the energy control procedure isolated all of the energy sources. Isolating all energy sources during cleaning operations under the automatic pile transfer and the autoplaten die cutter was not performed because the use of push buttons as energy isolating devices is prohibited.
Recent events (2)
  • — I (S) $4682
  • — Z (S) $7802

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2021
Abate by
Nov 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   On our about May 17, 2021, employees work under the Bobst SPO-2000 Automatic Pile Transfer and Platen Die Cutter to clean out cardboard scrap without affixing lockout tagout devices to each energy isolating device.