On , OSHA opened an unprogrammed Other safety inspection of GENESIS HOME IMPROVEMENT INC. in 1522-1524 NEW YORK AVENUE, BROOKLYN, NY 11210 (NAICS 238170). OSHA activity number 345369235.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENESIS HOME IMPROVEMENT INC.
- Site address
- 1522-1524 NEW YORK AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11210
- Mailing
- 35 MAPLE ROAD, INWOOD, NY 11096
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Jul 7, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: a) Supported scaffold on northeast side of the jobsite: On or about June 17, 2021, an employee was performing stucco work the first and second tier platform of a two-tier-high supported scaffold that was not fully planked or decked between front upright and the guardrail supports, and was exposed to falling up to approximately 13 feet to the lower level.
Recent events (1)
- — Z (S) $4096
1926.451 C03
- Issued
- Jul 7, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement Location: a) Supported scaffold on northeast side of the jobsite: On or about June 17, 2021, an employee was performing stucco work the first and second tier platform of a two-tier-high supported scaffold. The supported scaffold uprights were not braced to prevent swaying and displacement. The employee was exposed to falling up to approximately 13 feet to the lower level.
Recent events (1)
- — Z (S) $2926
1926.451 E01
- Issued
- Jul 7, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $2,926 · Current $2,926
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Scaffold frames were used as a means of access. Location: a) Supported scaffold on northeast side of the jobsite: On or about June 17, 2021, an employee was performing stucco work the first and second tier platform of a two-tier-high supported scaffold. He accessed the platform by climbing from the window. The employee was exposed to falling up to approximately 13 feet to the lower level.
Recent events (1)
- — Z (S) $2926
1926.451 G01 VII
- Issued
- Jul 7, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Supported scaffold on northeast side of the jobsite: On or about June 17, 2021, an employee was performing stucco work the first and second tier platform of a two-tier-high supported scaffold without the use of fall protection and was exposed to falling up to approximately 13 feet to the lower level.
Recent events (1)
- — Z (S) $4096
More inspections at Genesis Home Improvement INC.
View Genesis Home Improvement INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345369235.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.