Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALAMO BARBER & BEAUTY SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ALAMO BARBER & BEAUTY SUPPLY in 6301 BROADWAY, SAN ANTONIO, TX 78209 (NAICS 423850). OSHA activity number 345386783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alamo Barber & Beauty Supply — free Get an email when a new federal OSHA severe-injury report for Alamo Barber & Beauty Supply is published. One employer, no account, unsubscribe in one click.
Site address
6301 BROADWAY
City
SAN ANTONIO
State
TX
ZIP
78209
Mailing
6301 BROADWAY, SAN ANTONIO, TX 78209
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423850
Employees
5
Ownership type
A

7 citations on file for this inspection.

1910.242 B

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 15, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)  Barber Shop Station  #1 :  On or about June 24, 2021, and at times prior thereto, employees were exposed to a physical hazard when operating a compressed air blow gun to clean the body, where the tip pressure was not reduced to below 30 p.s.i.   b)  Barber Shop Station  #2:  On or about June 24, 2021, and at times prior thereto, employees were exposed to a physical hazard when operating a compressed air blow gun to clean the body, where the tip pressure was not reduced to below 30 p.s.i.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 15, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Storage Room, between office and shop:   On or about June 24, 2021, and at times prior thereto, the employer did not properly identify the circuit breakers to be disconnected for equipment in an electrical panel in the event of an electrical emergency.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

1910.303 G01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 15, 2021
Penalty
Initial $1,755 · Current $1,053 Reduced
29 CFR  1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:  Storage Room, between office and shop:  On or about June 24, 2021, and at times prior thereto, employees were exposed to an electrical panel that was obstructed by equipment and materials, which did not have a minimum of 3 feet of clearance in the event of an electrical emergency.
Recent events (2)
  • — I (S) $1053
  • — Z (S) $1755

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 15, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  Storage Room, between office and shop:   On or about June 16, 2021, and at times prior thereto, employees were exposed to an electrical hazard while working near the circuit breaker panel, where this panel had two missing breakers at location ABBS.   b) Storage Room, between office and shop:  On or about June 16, 2021, and at times prior thereto, employees were exposed to an electrical hazard while  working near the circuit breaker panel, where this panel had one missing breaker at location CH-9.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

1910.305 B02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 15, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a)  Storage Room, between office and shop:    On or about June 16, 2021, and at times prior thereto, employees were exposed to an electrical hazard while  working near the circuit breaker panel, where this panel had one missing cover.  a)  Storage Room, between office and shop:   On or about June 16, 2021, and at times prior thereto, employees were exposed to an electrical hazard from a receptacle that did not have a faceplate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 15, 2021
Abate by
Jan 4, 2022
Penalty
Initial $3,511 · Current $2,107 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables may not be used where run through holes in walls, ceilings or floors:  Backside of Beauty Salon:  On or about June 24, 2021,  and at times prior thereto, employees were exposed to an electrical hazard while using a flexible cord that was running through the floor on the inside to the exterior of the building.
Recent events (2)
  • — I (S) $2106.6
  • — Z (S) $3511

1910.334 A02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 15, 2021
Penalty
Initial $2,341 · Current $1,405 Reduced
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  Counter Area:  On or about June 16, 2021, and at times prior thereto, an employee was exposed to an electrical hazard while working with an extension cord that had strain relief damage at the plug.
Recent events (2)
  • — I (S) $1404.6
  • — Z (S) $2341

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345386783.