Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KELTON ENTERPRISES LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of KELTON ENTERPRISES LLC in 1950 SWEET HOME ROAD, AMHERST, NY 14228 (NAICS 722513). OSHA activity number 345387963.

Watch Kelton Enterprises LLC — free Get an email when a new federal OSHA severe-injury report for Kelton Enterprises LLC is published. One employer, no account, unsubscribe in one click.
Site address
1950 SWEET HOME ROAD
City
AMHERST
State
NY
ZIP
14228
Mailing
1950 SWEET HOME ROAD, AMHERST, NY 14228
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722513
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.303 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4973.00 · Current $3000.00 Reduced
29 CFR  1910.303(b)(1):Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a) Kitchen - On or about 6/29/21,  the top outlet of the dual outlet, 120v receptacle (used to power for the printer, tablet, portable phone via a three outlet adapter) was damaged and missing a section potentially exposing live electrical.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4973

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Kitchen - On or about 6/29/21, the three outlet adapter used to power the printer (3 amperes), tablet ( 2 amperes), and portable phone ( 200 milliamperes).  The three outlet adapter was plugged into a dual outlet receptacle (operating at 120 volts).   The three outlet adapter was not used or installed in accordance with instructions included in the listing or labeling.  ABATEMENT CERTIFICATION REQUIRED