OSHA Inspection: OSI GROUP, LLC DBA OSI INDUSTRIES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OSI GROUP, LLC DBA OSI INDUSTRIES, LLC in 4201 SOUTH ASHLAND AVENUE, CHICAGO, IL 60609 (NAICS 311612). OSHA activity number 345389183.

Watch OSI Group, LLC DBA OSI Industries, LLC — free Get an email when a new federal OSHA severe-injury report for OSI Group, LLC DBA OSI Industries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4201 SOUTH ASHLAND AVENUE
City
CHICAGO
State
IL
ZIP
60609
Mailing
4201 SOUTH ASHLAND AVENUE, CHICAGO, IL 60609
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311612
Employees
545
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $13653.00
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  a.) On or about June 18, 2021,  the employer failed to provide training to each authorized employee performing service and/or maintenance to machinery or equipment, including Armor Inox Tank #3, to ensure the employee acquired the knowledge and skills required for the safe application, usage and removal of energy control devices.
Recent events (2)
  • — I (S) $13653
  • — Z (S) $13653

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $0.00 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a)  Armor Inox Room - On or about June 18, 2021, an employee was exposed to machine hazards associated with thermal energy while tightening the clover tri-clamp on Armor Inox Tank #3.  The employer failed to implement energy control application steps as the machine as not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.