Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: OLIN CORPORATION WINCHESTER LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OLIN CORPORATION WINCHESTER LLC in 33 CR 166, OXFORD, MS 38655 (NAICS 332992). OSHA activity number 345393904.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Olin Corporation Winchester LLC for free Get an email when a new federal OSHA severe-injury report for Olin Corporation Winchester LLC is published. One employer, no account, unsubscribe in one click.
Site address
33 CR 166
City
OXFORD
State
MS
ZIP
38655
Mailing
33 CR 166, OXFORD, MS 38655
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332992
Employees
1250
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 D03

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 10, 2021
Abate by
Sep 1, 2021
Penalty
Initial $11,703 · Current $7,022 Reduced
29 CFR  1910.147(d)(3):Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).  (a) No. 52 Heading Pocketing Press - On or about June 29, 2021 employees completing quality check did not isolate the air and electrical energy sources exposing the employees to amputation hazards.
Recent events (2)
  • · I (S) $7021.8
  • · Z (S) $11703

1910.147 D04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 10, 2021
Abate by
Sep 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.   (a) No. 52 Heading Pocketing Press - On or about June 29, 2021 the employer did not ensure authorized employees install a locking device to energy isolating mechanisms prior to performing quality checks exposing employees to amputation hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345393904.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.