OSHA Inspection: DECKING TEXAS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DECKING TEXAS, INC. in 251 NORTH WESTERN BLVD, DENTON, TX 76207 (NAICS 238190). OSHA activity number 345399265.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Decking Texas, INC. for free Get an email when a new federal OSHA severe-injury report for Decking Texas, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DECKING TEXAS, INC.
Site address
251 NORTH WESTERN BLVD
City
DENTON
State
TX
ZIP
76207
Mailing
11005 INDIAN TRAIL #106, DALLAS, TX 75229
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
16
Ownership type
Private (A)

3 citations on file for this inspection.

1926.20 B01

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Aug 12, 2021
Abate by
Sep 10, 2021
Penalty
Initial $2,340 · Current $0 Reduced
29 CFR  1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:   On or about July 1, 2021 and times prior thereto, the employer did not frequently inspect the work site to ensure fall protection was used at all times where employees were expose to fall hazards and failed to correct unsafe hazards associated with installation of  roof decking.
Recent events (3)
  • · F (S) $0
  • · C (S) $2340
  • · Z (S) $2340

1926.760 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 12, 2021
Abate by
Sep 10, 2021
Penalty
Initial $3,901 · Current $3,500 Reduced
29 CFR  1926.760(c)(1): Each employee working at the leading edge in a CDZ was not protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less.   On or about July 1, 2021 and times prior thereto, the employer did not ensure the employees, while installing roof panels, was attached to lifelines to prevent exposure to a fall hazard of approximately 35 feet to the lower level.
Recent events (3)
  • · F (S) $3500
  • · C (S) $3901
  • · Z (S) $3901

1926.760 D02

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Aug 12, 2021
Abate by
Sep 10, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.760(d)(2): Fall arrest system components  used in fall restraint systems did not conform to the criteria in 1926.502.    On or about July 1, 2021 and times prior thereto, the employer did not ensure the fall restraint systems such as cable lifelines and retractable devices were used at all times while employees worked on the roof exposing them to fall hazard of approximately 35 feet to the lower level.
Recent events (3)
  • · F (O) $0
  • · C (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345399265.