DENTON, TX ·
OSHA Inspection: DECKING TEXAS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DECKING TEXAS, INC. in 251 NORTH WESTERN BLVD, DENTON, TX 76207 (NAICS 238190). OSHA activity number 345399265.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DECKING TEXAS, INC.
- Site address
- 251 NORTH WESTERN BLVD
- City
- DENTON
- State
- TX
- ZIP
- 76207
- Mailing
- 11005 INDIAN TRAIL #106, DALLAS, TX 75229
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 16
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.20 B01
- Issued
- Aug 12, 2021
- Abate by
- Sep 10, 2021
- Penalty
- Initial $2,340 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: On or about July 1, 2021 and times prior thereto, the employer did not frequently inspect the work site to ensure fall protection was used at all times where employees were expose to fall hazards and failed to correct unsafe hazards associated with installation of roof decking.
Recent events (3)
- · F (S) $0
- · C (S) $2340
- · Z (S) $2340
1926.760 C01
- Issued
- Aug 12, 2021
- Abate by
- Sep 10, 2021
- Penalty
- Initial $3,901 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.760(c)(1): Each employee working at the leading edge in a CDZ was not protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less. On or about July 1, 2021 and times prior thereto, the employer did not ensure the employees, while installing roof panels, was attached to lifelines to prevent exposure to a fall hazard of approximately 35 feet to the lower level.
Recent events (3)
- · F (S) $3500
- · C (S) $3901
- · Z (S) $3901
1926.760 D02
- Issued
- Aug 12, 2021
- Abate by
- Sep 10, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.760(d)(2): Fall arrest system components used in fall restraint systems did not conform to the criteria in 1926.502. On or about July 1, 2021 and times prior thereto, the employer did not ensure the fall restraint systems such as cable lifelines and retractable devices were used at all times while employees worked on the roof exposing them to fall hazard of approximately 35 feet to the lower level.
Recent events (3)
- · F (O) $0
- · C (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238190)