Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EGGERS DIVISION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EGGERS DIVISION, LLC in ONE EGGER DRIVE, TWO RIVERS, WI 54241 (NAICS 321911). OSHA activity number 345400402.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eggers Division, LLC — free Get an email when a new federal OSHA severe-injury report for Eggers Division, LLC is published. One employer, no account, unsubscribe in one click.
Site address
ONE EGGER DRIVE
City
TWO RIVERS
State
WI
ZIP
54241
Mailing
P.O. BOX 88, TWO RIVERS, WI 54241
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
225
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2021
Abate by
Dec 27, 2021
Penalty
Initial $13,653 · Current $6,826 Reduced
29 CFR  1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    On or about June 28, 2021, the employer's lockout procedure for the Double End Tenorer (DET) did not specify the coast down time needed to delay the entry of the authorized employee to the hogger blades. The blades took 6 to 7 minutes to stop motion once the electrical energy was disconnected and locked out. An employee suffered multiple injuries to the right hand from contact with the right hogger blade when attempting to remove a jammed door from the DET machine's first pass section.
Recent events (2)
  • — I (S) $6826
  • — Z (S) $13653

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2021
Abate by
Feb 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    On or about July 6, 2021, the employer had not conducted a periodic inspection of the energy control procedures at least annually to ensure that the procedure and the requirements of this standard were being followed for employees engaged in servicing and/or maintenance tasks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2021
Abate by
Dec 27, 2021
Penalty
Initial $13,653 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  On or about June 28, 2021, the employer had not trained each authorized employee on the methods to ensure all residual energy had been dissipated from the Double End Tenorer machine prior to initiating servicing and/or maintenance activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13653

1910.147 D

Repeat Gravity 10 1 instance 3 exposed
Issued
Dec 3, 2021
Abate by
Dec 27, 2021
Penalty
Initial $75,092 · Current $37,546 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:   On or about June 28, 2021, on the Double End Tenorer (DET), an employee was exposed to machine hazards associated with rotating cutting blades while attempting to unjam a door. The employer did not ensure that employees implemented energy control application steps prior to unjamming the DET. The machine was not deenergized prior to the employee engaging in the servicing/maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], LOTO device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from machine servicing hazards.  Eggers Industries, Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.147(d), which was contained in OSHA inspection number 1196154, citation number 1, item 1a and was affirmed as a final order on February 22, 2017, with respect to a workplace located at 164 N. Lake Street, Neenah, WI 54956.
Recent events (2)
  • — I (R) $37546
  • — Z (R) $75092

View Eggers Division, LLC's full OSHA safety record →