IDAHO FALLS, ID —
OSHA Inspection: MOUNTAIN VALLEY CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MOUNTAIN VALLEY CONSTRUCTION, INC. in 373 COACHMAN DRIVE, IDAHO FALLS, ID 83402 (NAICS 238910). OSHA activity number 345400568.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOUNTAIN VALLEY CONSTRUCTION, INC.
- Site address
- 373 COACHMAN DRIVE
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83402
- Mailing
- PO BOX 311, REXBURG, ID 83440
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 1
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B02
- Issued
- Sep 10, 2021
- Abate by
- Sep 16, 2021
- Penalty
- Initial $9,557 · Current $4,779 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a) On July 2, 2021 and at times prior thereto; the controlling employer, Mountain Valley Construction, Inc., did not have an effective system in place to effectively identify and have corrected hazards to which their subcontractors were exposed. A sub-contractor employee was exposed to a 15 foot fall hazard while performing siding work from a ladder jack scaffold that was not correctly planked, and without using fall protection. b) On July 2, 2021 and at times prior thereto; the controlling employer, Mountain Valley Construction, Inc., did not have an effective system in place to effectively identify and have corrected hazards to which their subcontractors were exposed. A sub-contractor employee was exposed to a fall hazard while working from an aerial lift without using fall protection. Note) Certification and documentation of corrective actions are required for these items.
Recent events (2)
- — I (S) $4778.5
- — Z (S) $9557
1926.451 G01 I
- Issued
- Sep 10, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system; a) Building 1: On July 2, 2021 and at times prior thereto; the controlling employer, Mountain Valley Construction, Inc., did not ensure its sub-contractor protected their employees while performing siding work from a ladder jack scaffold system. A subcontractor employee was not using fall arrest and was exposed to a 15 foot fall hazard to the ground below. Note) Corrected during inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 K05
- Issued
- Sep 10, 2021
- Abate by
- Sep 16, 2021
- Penalty
- Initial $9,557 · Current $4,779 Reduced
General-duty citation text
29 CFR 1926.452(k)(5): Scaffold platforms were bridged one to another: a) Building 1: On July 2, 2021 and at times prior thereto; the controlling employer, Mountain Valley Construction, Inc., did not ensure its sub-contractor protected their employees while performing siding work from a ladder jack scaffold system. A concrete bar was used to pin two, 16 foot long aluminum scaffold planks together at the center ladder jack bracket, exposing the employee to a scaffold failure and 15 foot fall hazard. Note) Documentation and certification of corrective action are required for this item.
Recent events (2)
- — I (S) $4778.5
- — Z (S) $9557
1926.453 B02 V
- Issued
- Sep 10, 2021
- Penalty
- Initial $6,827 · Current $3,414 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): Personal fall protection and lanyard were not worn and attached to the boom or basket when working from an aerial lift: a) Building 1: On July 2, 2021 and at times prior thereto; the controlling employer, Mountain Valley Construction, Inc., did not ensure its sub-contractor protected their employees while performing siding work from an aerial lift. The subcontractor employee worked without fall protection. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e). Note) Corrected during inspection.
Recent events (2)
- — I (S) $3413.5
- — Z (S) $6827
More inspections at Mountain Valley Construction, INC.
View Mountain Valley Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345400568.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.