OSHA Inspection: TEAM ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEAM ERECTORS, INC. in 151 NORTH QUEEN STREET, LANCASTER, PA 17603 (NAICS 238120). OSHA activity number 345402192.

Watch Team Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Team Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TEAM ERECTORS, INC.
Site address
151 NORTH QUEEN STREET
City
LANCASTER
State
PA
ZIP
17603
Mailing
P.O. BOX 23, LINCOLN UNIVERSITY, PA 19352
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
9
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5803.00 · Current $13653.00
OSH ACT of 1970 Section (5)(a)(1)  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees :  (a) Fourth Level - On or about June 24, 2021, employees performing precast concrete work did not complete this work while using fall protection equipment and methods that were 100 percent effective  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $13653
  • — Z (S) $5803

1926.502 D21

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  (a) Fourth Level - An employee erecting precast concrete double tees at a leading edge used a Guardian Velocity self-retracting lifeline as part of a personal fall arrest system.  The labeling and markings, including the model, serial number, and safety instructions, on this self-retracting life had become illegible due to wear, and this personal fall arrest component did not get removed from service, exposing the employee to a fall hazard, on or about June 24, 2021.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B12

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4642.00 · Current $0.00 Reduced
29 CFR  1926.501(b)(12): Each employee engaged in the erection of precast concrete members (including, but not limited to the erection of wall panels, columns, beams, and floor and roof "tees") and related operations such as grouting of precast concrete members, who was 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems, unless another provision in paragraph (b) of this section provided for an alternative fall protection measure:  (a) Fourth Level - Employees worked with a crane to set precast concrete double tees on the fourth level above the ground.  The employer's written fall protection plan specified using 100 percent conventional fall protection, to include the use of personal fall arrest systems by employees working at the leading edge while setting double tees.  An employee setting double tees did not follow the employer's written fall protection plan in that this employee disconnected his personal fall arrest system from an anchorage point and worked while not tied off, exposing the employee to falling at least 10 feet to a lower level, on or about June 24, 2021.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4642

1926.502 G01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6827.00 · Current $0.00 Reduced
29 CFR  1926.502(g)(1)(i): When control lines were used, they were not erected not less than 6 feet (1.8 m) nor more than 25 feet (7.7 m) from the unprotected or leading edge, except when erecting precast concrete members:  (a) Fourth Level, South East Section of the Building - The employer's written fall protection plan specified using a Control Zone System (i.e., Controlled Access Zone) at leading edge and perimeter areas as an alternative fall protection measure during precast concrete erection related activities.  The employer installed a control line along a 31-foot long unprotected edge in the perimeter at the south west facing side of the south east section of the building, but this control line was less than 6 feet back from the unprotected edge, exposing employees to the hazard of falling from the fourth floor to the ground below, on or about June 24, 2021.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6827