Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WALLACE HOME IMPROVEMENT

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of WALLACE HOME IMPROVEMENT in 267 ODLIN ROAD, BANGOR, ME 04401 (NAICS 238160). OSHA activity number 345403208.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wallace Home Improvement — free Get an email when a new federal OSHA severe-injury report for Wallace Home Improvement is published. One employer, no account, unsubscribe in one click.
Site address
267 ODLIN ROAD
City
BANGOR
State
ME
ZIP
04401
Mailing
7 WALLACE AVENUE, GRAY, ME 04039
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Serious Gravity 10 5 instances 5 exposed
Issued
Sep 15, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR  1926.501(b)(10):29 CFR 1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone:  Commercial Business Roof - The general contactor did not ensure that five subcontracted employees, working greater than 15 feet above the ground, were protected from falling.
Recent events (2)
  • — I (S) $2867.2
  • — Z (S) $4096

View Wallace Home Improvement's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345403208.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.