MILWAUKEE, WI —
OSHA Inspection: WIXON INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WIXON INC. in 1450 E. BOLIVAR AVENUE, MILWAUKEE, WI 53235 (NAICS 311999). OSHA activity number 345407191.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WIXON INC.
- Site address
- 1450 E. BOLIVAR AVENUE
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53235
- Mailing
- 1390 E. BOLIVAR AVENUE, MILWAUKEE, WI 53235
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 219
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II D
- Issued
- Oct 22, 2021
- Abate by
- Nov 18, 2021
- Penalty
- Initial $8,778 · Current $8,778
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy controls: (a) On or about July 8, 2021, at the worksite located at 1450 E. Bolivar Avenue, Saint Francis, WI, the employer did not ensure the established procedure clearly and specifically outlined the requirements for testing the equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy controls. Hazardous energy control procedures were established for the Effytec feeder system # 16, however, the procedures did not contain adequate information pertaining to, at minimum, the verification that hazardous energy was isolated. (b) On or about July 8, 2021, at the worksite located at 1450 E. Bolivar Avenue, Saint Francis, WI, the employer did not ensure the established procedure clearly and specifically outlined the requirements for testing the equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy controls. Hazardous energy control procedures were established for the Effytec feeder system # 17, however, the procedures did not contain adequate information pertaining to, at minimum, the verification that hazardous energy was isolated.
Recent events (2)
- — I (S) $8778
- — Z (S) $8778
1910.147 D
- Issued
- Oct 22, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $8,778 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about July 8, 2021, at the worksite located at 1450 E. Bolivar Avenue, Saint Francis, WI, on the Effytec machine, the employer did not ensure the established procedure for the application of energy control covered the actions listed and was performed in sequence as required by 29 CFR 1910.147(d)(1)-(6) when performing service and maintenance activities. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from the unexpected energization, startup, or release of stored energy during machine servicing and maintenance activities.
Recent events (2)
- — I (S) $0
- — Z (S) $8778
1910.147 C06 II
- Issued
- Oct 22, 2021
- Abate by
- Nov 18, 2021
- Penalty
- Initial $8,778 · Current $8,778
General-duty citation text
1910.147(c)(6)(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. 29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected(a): (a) On or about July 8, 2021, at the worksite located at 1450 E. Bolivar Avenue, Saint Francis, WI, the employer did not ensure the periodic inspection included a review between the inspector and each authorized employee, and the employee's responsibilities under the energy control procedure being inspected. The periodic review of hazardous energy control procedures did not include a review of all persons who are authorized to utilize lockout devices and procedures for controlling hazardous energy for equipment such as, but not limited to, the Effytec feeder systems.
Recent events (2)
- — I (O) $8778
- — Z (S) $8778
1910.147 C07 I
- Issued
- Oct 22, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $8,778 · Current $8,778
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) On or about July 8, 2021, at the worksite located at 1450 E. Bolivar Avenue, Saint Francis, WI, the employer did not ensure training was provided to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees who utilize hazardous energy control, or, who are responsible for work tasks such as, but not limited to, set-up, clearing jams, cleaning, clearing debris, etc.
Recent events (2)
- — I (O) $8778
- — Z (S) $8778
1910.212 A01
- Issued
- Oct 22, 2021
- Abate by
- Nov 18, 2021
- Penalty
- Initial $8,778 · Current $6,144 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about July 8, 2021, at the worksite located at 1450 E. Bolivar Avenue, Saint Francis, WI, the employer did not ensure machine guarding was provided to protect employees from hazards created by point of operation, ingoing nip points, rotating parts, etc. Effytec machine # 16 and # 17 contained a loading hopper that did not have adequate guarding to protect workers from rotating auger components.
Recent events (2)
- — I (S) $6144
- — Z (S) $8778
More inspections at Wixon INC.
View Wixon INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345407191.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.