OSHA Inspection: N&B WOOD INSTALLER LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of N&B WOOD INSTALLER LLC in 40 N STREET NE, WASHINGTON, DC 20002 (NAICS 238130). OSHA activity number 345417935.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch N&B Wood Installer LLC — free Get an email when a new federal OSHA severe-injury report for N&B Wood Installer LLC is published. One employer, no account, unsubscribe in one click.
Site address
40 N STREET NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
2902 INDIANSUMMER CRT, ABINGDON, MD 21009
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

1 citation on file for this inspection.

1926.404 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Jan 13, 2022
Abate by
Jan 20, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure, and which are in use by employees, did not have approved ground fault circuit interrupters for personal protection.  a) On or about July 13, 2021; throughout the building; employees were operating double insulated electrical equipment such as, but not limited to, portable circular saws without ground-fault interrupters in place to protect from electrical shock.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).