ARLINGTON HEIGHTS, IL —
OSHA Inspection: SHANLEY PUMP & EQUIPMENT INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SHANLEY PUMP & EQUIPMENT INC. in 2525 SOUTH CLEARBROOK DRIVE, ARLINGTON HEIGHTS, IL 60005 (NAICS 423440). OSHA activity number 345420269.
Where did this inspection happen?
- Establishment
- SHANLEY PUMP & EQUIPMENT INC.
- Site address
- 2525 SOUTH CLEARBROOK DRIVE
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60005
- Mailing
- 2525 SOUTH CLEARBROOK DRIVE, ARLINGTON HEIGHTS, IL 60005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423440
- Employees
- 35
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.252 B02 III
- Issued
- Penalty
- Initial $4096.00 · Current $3736.00 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) On or about July 13, 2021, Shanley Pump & Equipment Inc. did not protect its employee working in the welding area and other employees adjacent to the welding area from welding rays by noncombustible or flameproof screens or shields. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $3735.58
- — Z (S) $4096
1910.1026 D01
- Issued
- Abate by
- Penalty
- Initial $6827.00 · Current $767.00 Reduced
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) On or about July 13, 2021, Shanley Pump & Equipment Inc. did not determine the 8-hour time-weighted average exposure for an employee exposed to chromium (VI) when welding on stainless steel. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $767
- — Z (S) $6827
1910.1026 L01 III
- Issued
- Abate by
- Penalty
- Initial $6827.00 · Current $5320.00 Reduced
General-duty citation text
29 CFR 1910.1026(l)(1)(iii): Employers shall include chromium (VI) in the hazard communication program established to comply with the HCS (� 1910.1200). Employers shall ensure that each employee has access to labels on containers of chromium (VI) and to safety data sheets, and is trained in accordance with the requirements of HCS and paragraph (l)(2) of this section. a) On or about July 13, 2021, Shanley Pump & Equipment Inc. did not include chromium (VI) in the hazard communication program established to comply with the hazard communication standard. An employee working in the welding area was exposed to chromium (VI) when welding on stainless steel. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $5319.56
- — Z (S) $6827
1910.1200 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) On July 15, 2021, Shanley Pump & Equipment Inc. did not develop, implement, and/or maintain at the workplace a written hazard communication program which described how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) would be met. Employees were exposed to chemicals including, but not limited to acetone, propane, n-butyl acetate (Krylon Fusion Gloss); polyglycol dimethacrylate (Loctite 242 Threadlocker). No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical a) On July 15, 2021, Shanley Pump & Equipment Inc. did not maintain SDSs in the workplace for employees welding and/or spray painting. Employees were exposed to chemicals including, but not limited to acetone, propane, n-butyl acetate (Krylon Fusion Gloss); polyglycol dimethacrylate (Loctite 242 Threadlocker); and dichloromethane (Zip Strip Paint and Finish Remover). No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On July 15, 2021, Shanley Pump & Equipment Inc. did not provide an employee with training regarding the health hazards associated with hazardous chemicals in his work area. An employee was exposed to chemicals including, but not limited to acetone, propane and n-butyl acetate when spray painting various parts and pieces of pumps with Krylon Fusion Gloss spray paint. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) On July 27, 2021, Shanley Pump & Equipment Inc. did not provide the information contained in Appendix D to an employee that was permitted to voluntarily use a 3M 6200 half face respirator while spray painting. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $767.00 · Current $445.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) On July 27, 2021, Shanley Pump & Equipment Inc. did not provide a medical evaluation to determine an employee's ability to wear a 3M 6200 half face tight-fitting negative pressure respirator before he was allowed to voluntarily use it while spray painting. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $444.86
- — Z (O) $767
More inspections at SHANLEY PUMP & EQUIPMENT INC.
ARLINGTON HEIGHTS, IL—2021-07-15 00:00:00
SHANLEY PUMP & EQUIPMENT INC.
View SHANLEY PUMP & EQUIPMENT INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423440)
HARWOOD HEIGHTS, IL—2026-07-08
TOMATO MOUNTAIN FARM LLC
JOLIET, IL—2026-06-08
UNFI
ROSEMONT, IL—2026-05-29
PUEGEOT SAVEURS NORTH AMERICA LLC
WRENTHAM, MA—2026-05-14
REX POWER MAGNETICS
BALTIMORE, MD—2026-05-11
CLARK ASSOCIATES
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345420269.