2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: EVOLUTION ROOFING CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EVOLUTION ROOFING CORP in 660 BRIDGE STREET, LOWELL, MA 01850 (NAICS 238160). OSHA activity number 345420517.

Watch Evolution Roofing Corp — free Get an email when a new federal OSHA severe-injury report for Evolution Roofing Corp is published. One employer, no account, unsubscribe in one click.
Site address
660 BRIDGE STREET
City
LOWELL
State
MA
ZIP
01850
Mailing
205 PRATT AVE, APT 21, LOWELL, MA 01851
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.416(a)(1):  Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.  (a) Location - 660 Bridge, Lowell, MA:  On or about 7/15/2021,  employees were exposed to electric shock and/or electrocution hazards while performing roof replacement activities in the direct vicinity of energized electrical circuits.
Recent events (1)
  • — Z (S) $4096

1926.502 D

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.502(d):The employer used body belts as part of a personal fall arrest system.  (a) Location - 660 Bridge Street, Lowell, MA:  On or about 7/15/2021, employees were allowed to use body belts as a primary means of personal fall arrest, thereby exposing employees to internal injuries from falls greater than 20 feet.
Recent events (1)
  • — Z (S) $4096

1926.502 D15

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.502(d)(15):  Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  (a) Location - 660 Bridge, Lowell, MA:  On or about 7/15/2021, employees were not protected from falling when more than one employee was attached to a single anchor.
Recent events (1)
  • — Z (S) $4096

1926.502 D17

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(d)(17):  The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head.  (a) Location - 660 Bridge, Lowell, MA:  On or about 7/15/2021,  employees were exposed to falls grater than 20 feet while utilizing life lines connected directly to the front/waist positioning ring and not using D-rings located at the center of back.
Recent events (1)
  • — Z (S) $0

View EVOLUTION ROOFING CORP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345420517.